<small> ''Blanks not listed in stationpedia, assumed to be zero''</small> | <small> ''Blanks not listed in stationpedia, assumed to be zero''</small> | ||
| − | =external links= | + | ===Heat Exchangers=== |
| + | Heat exchangers are different from most other atmospheric devices because they operate between pipe networks instead of an internal volume and outside atmosphere. Heat transfer between two networks follows the same rules as thermal convection. | ||
| + | {| class="wikitable sortable" | ||
| + | |- | ||
| + | ! Exchanger !! Thermal Convection | ||
| + | |- | ||
| + | | <div class="stationeers-icon">[[image:Small direct heat exchanger gas to gas.png]]</div> [[Kit (Small Direct Heat Exchanger)|Small Direct Heat Exchanger]] || 1 | ||
| + | |- | ||
| + | | <div class="stationeers-icon">[[image:Stationeers large direct heat exchanger gas to gas.png]]</div> [[Kit (Large Direct Heat Exchanger)|Large Direct Heat Exchanger]] || 8 | ||
| + | |- | ||
| + | | <div class="stationeers-icon"></div> [[Kit (Super Large Direct Heat Exchanger)|Super Large Direct Heat Exchanger]] || 28 | ||
| + | |} | ||
| + | [[Kit (Counterflow Heat Exchanger)|Counterflow heat exchangers]] are not easily comparable to direct heat exchangers. See external link below. | ||
| + | ==External links== | ||
* [https://discord.com/channels/276525882049429515/395912153795788803/1393151312983621703 Discord post containing formulas for radiation and convection ] | * [https://discord.com/channels/276525882049429515/395912153795788803/1393151312983621703 Discord post containing formulas for radiation and convection ] | ||
* [https://discord.com/channels/276525882049429515/395912153795788803/1398761976477384755 Discord post containing formulas for counterflow heat exchanger] | * [https://discord.com/channels/276525882049429515/395912153795788803/1398761976477384755 Discord post containing formulas for counterflow heat exchanger] | ||
Latest revision as of 18:21, 23 December 2025
This is a collection of thermal convection, radiation, and solar heating values for easy comparison to one another.
Pipe Network[edit]
Note that all equivalent liquid structures have the same values as their gas counterparts, except for the Liquid Pipe Convection Radiator which is listed separately.
Insulated tanks, pipes and in-line tanks have zero for all values.
Solar heating does not seem to apply to pipe-mounted radiators.
| Pipe Network Structure | Thermal Convection | Thermal Radiation | Solar Heating |
|---|---|---|---|
| Pipe | 0.005 | 0.001* | 0.05 |
| Pipe Radiator | 0.231 | 3.46 | 2.31 |
| Pipe Convection Radiator | 1.05 | 0.79 | 0.105 |
| Liquid Pipe Convection Radiator | 1.02 | 0.763 | 0.102 |
| Medium Radiator | 1.5 | 30 | 15 |
| Medium Convection Radiator | 9.38 | 3 | 1.5 |
| Large Extendable Radiator | 0.736 | 73.6 | 950 (at 100% efficiency)* |
| Small Tank | 0.758 | 0.03 | 1.52 |
| Large Tank | 4.24 | 0.17 | 8.49 |
| In-Line Tank Gas | 0.025 | 0.001 | 0.25 |
| In-Line Tank Small Gas | 0.015 | 0.001 | 0.152 |
* Not listed in stationpedia, approximated value
Items[edit]
Note that Gas Tank MKII and liquid variant are insulated, with zeros for all values
| Item | Thermal Convection | Thermal Radiation | Solar Heating |
|---|---|---|---|
| Gas Canister | 0.04 | 0.04 | 0.081 |
| Liquid Canister | 0.041 | 0.041 | 0.082 |
| Gas Canister (Smart) | 0.081 | 0.081 | 0.081 |
| Liquid Canister (Smart) | 0.084 | 0.084 | 0.084 |
| Portable Gas Tank | 0.129 | 0.129 | 0.515 |
| Portable Liquid Tank | 0.129 | 0.129 | 0.515 |
Devices[edit]
| Device | Thermal Convection | Thermal Radiation | Solar Heating |
|---|---|---|---|
| Furnace | 0.816 | 0.816 | 4.08 |
| Advanced Furnace | 1.35 | 1.35 | 1.35 |
| H2 Combustor | 0.506 | 0.506 | 0.506 |
| Electrolyzer | 0.526 | 0.526 | 0.526 |
| Evaporation Chamber | 0.007 | 0.747 | |
| Condensation Chamber | 0.007 | 0.742 | |
| Hydroponics Tray | 0.014 | 0.001 | 0.145 |
| Hydroponics Device | 0.146 | 0.146 | 0.146 |
Blanks not listed in stationpedia, assumed to be zero
Suits[edit]
| Suit | Thermal Convection | Thermal Radiation | Solar Heating |
|---|---|---|---|
| Space Helmet | 1.26 | ||
| EVA Suit | 0.205 | 0.205 | 8.19 |
| Hardsuit Helmet | |||
| Hardsuit | 0.062 | 0.062 | 6.23 |
| HARM Helmet | |||
| HARM Suit | 0.04 | 0.159 | |
| Emergency EVA Helmet | 1 | ||
| Emergency EVA Suit | 0.132 | 0.132 | 0.662 |
Blanks not listed in stationpedia, assumed to be zero
Heat Exchangers[edit]
Heat exchangers are different from most other atmospheric devices because they operate between pipe networks instead of an internal volume and outside atmosphere. Heat transfer between two networks follows the same rules as thermal convection.
| Exchanger | Thermal Convection |
|---|---|
| Small Direct Heat Exchanger | 1 |
| Large Direct Heat Exchanger | 8 |
| Super Large Direct Heat Exchanger | 28 |
Counterflow heat exchangers are not easily comparable to direct heat exchangers. See external link below.