Difference between revisions of "Back Pressure Regulator"
From Unofficial Stationeers Wiki
Emilgardis (talk | contribs) (Redirect Back Pressure Regulator to Pressure Regulator anchor) |
Emilgardis (talk | contribs) (rework back pressure regulator page) |
||
Line 1: | Line 1: | ||
− | + | [[Category:Atmospherics]] | |
+ | {{Structurebox | ||
+ | | name = Back Pressure Regulator | ||
+ | | image = [[File:StructureBackPressureRegulator.png]] | ||
+ | | prefab_hash = -1149857558 | ||
+ | | prefab_name = StructureBackPressureRegulator | ||
+ | | power_usage = 100W | ||
+ | | placed_on_grid = Small Grid | ||
+ | | decon_with_tool1 = [[Hand Drill]] | ||
+ | | placed_with_item = [[Kit (Pressure Regulator)]] | ||
+ | | item_rec1 = [[Kit (Pressure Regulator)]] | ||
+ | }} | ||
+ | ==Description== | ||
+ | <blockquote><q>Unlike the [[Pressure Regulator]], which closes when the input exceeds a given pressure, the back pressure regulator opens when input pressure reaches a given value.</q><br> | ||
+ | '''- Stationpedia'''</blockquote> | ||
+ | The Back Pressure Regulator will only pass through gases when the pressure on its intake side exceeds the set value. In other words, the standard Regulator defaults '''open''' and closes when the ''output'' is overpressured, while the Back Pressure Regulator defaults '''closed''' and opens when the ''input'' is overpressured. | ||
+ | |||
+ | Like the standard Regulator, the Back Pressure Regulator also acts as a check valve, switched valve, and compressor (i.e., input gas will move even if the output is already a higher pressure). | ||
+ | |||
+ | Its low flow rate makes it not suitable for being used as an emergency dump valve. | ||
+ | |||
+ | To calculate the moles per tick, use the following equation: | ||
+ | n = (P * V) / (R * T) | ||
+ | |||
+ | Where: | ||
+ | * P = Min(Input pressure, 101.325) | ||
+ | * V = 100 | ||
+ | * n = Moles per tick | ||
+ | * R = Gas constant (8.3144) | ||
+ | * T = Input temperature | ||
+ | |||
+ | {{Data Network Header}} | ||
+ | {{Data Parameters| | ||
+ | {{Data Parameters/row|Power|Boolean|w=0|Can be read to return if the Back Pressure Regulator is correctly powered or not, set via the power system, return 1 if powered and 0 if not|multiple=2|0|Unpowered|1|Powered}} | ||
+ | {{Data Parameters/row|Error|Boolean|w=0|1 if device is in error state, otherwise 0|multiple=2|0|<p></p>|1|Error}} | ||
+ | {{Data Parameters/row|Lock|Boolean|Disable manual operation of the Back Pressure Regulator.|multiple=2|0|Unlocked|1|Locked}} | ||
+ | {{Data Parameters/row|Setting|Integer|A variable setting that can be read or written.|0.0 to 60795.0}} | ||
+ | {{Data Parameters/row|Maximum|Float|w=0|Maximum setting of the Back Pressure Regulator}} | ||
+ | {{Data Parameters/row|Ratio|Float|w=0|Context specific value depending on device, 0 to 1 based ratio|0.0 to 1.0}} | ||
+ | {{Data Parameters/row|On|Boolean|The current state of the Back Pressure Regulator.|multiple=2|0|Off|1|On}} | ||
+ | {{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}} | ||
+ | {{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}} | ||
+ | {{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}} | ||
+ | {{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32 bit integer.}} | ||
+ | }} |
Revision as of 05:59, 10 July 2024
File:StructureBackPressureRegulator.png | |
Operation | |
---|---|
Power Usage | 100W |
Prefab Hash | -1149857558 |
Prefab Name | StructureBackPressureRegulator |
Construction | |
Placed with | Kit (Pressure Regulator) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Pressure Regulator) |
Description
Unlike the Pressure Regulator, which closes when the input exceeds a given pressure, the back pressure regulator opens when input pressure reaches a given value.
- Stationpedia
The Back Pressure Regulator will only pass through gases when the pressure on its intake side exceeds the set value. In other words, the standard Regulator defaults open and closes when the output is overpressured, while the Back Pressure Regulator defaults closed and opens when the input is overpressured.
Like the standard Regulator, the Back Pressure Regulator also acts as a check valve, switched valve, and compressor (i.e., input gas will move even if the output is already a higher pressure).
Its low flow rate makes it not suitable for being used as an emergency dump valve.
To calculate the moles per tick, use the following equation: n = (P * V) / (R * T)
Where:
- P = Min(Input pressure, 101.325)
- V = 100
- n = Moles per tick
- R = Gas constant (8.3144)
- T = Input temperature
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Back Pressure Regulator is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
1 | Error | |||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Back Pressure Regulator. | |
1 | Locked | |||||
Setting | Integer | Read Write
|
0.0 to 60795.0 | |||
Maximum | Float | Read
|
||||
Ratio | Float | Read
|
0.0 to 1.0 | |||
On | Boolean | Read Write
|
0 | Off | The current state of the Back Pressure Regulator. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|