Difference between revisions of "Data Parameters"
From Unofficial Stationeers Wiki
Emilgardis (talk | contribs) |
Emilgardis (talk | contribs) (add articles with this template to Category:Data Network) |
||
Line 15: | Line 15: | ||
|{{#if: {{{empty|}}}|This device does not have any logic parameters and can not be selected with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]].| These are all parameters that can be written with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]], [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]], or [[Integrated Circuit (IC10)]]. }} | |{{#if: {{{empty|}}}|This device does not have any logic parameters and can not be selected with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]].| These are all parameters that can be written with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]], [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]], or [[Integrated Circuit (IC10)]]. }} | ||
}} | }} | ||
+ | {{#if: {{{empty|}}}||{{#if: {{{1|}}}| [[Category:Data Network]] }} }} | ||
<noinclude> | <noinclude> | ||
{{Documentation}} | {{Documentation}} |
Revision as of 06:15, 19 May 2024
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Data Parameters template
This template is meant to be used for Structures, that support connections to the Data Network. It provides a heading for Data parameters. If anything is passed to the first positional parameter of the template, it will display a text that indicates, that the structure does not have any parameters.
The above documentation is transcluded from Template:Data Parameters/doc. (edit | history) Editors can experiment in this template's sandbox (edit | diff) and testcases (create) pages. Please add categories to the /doc subpage. Subpages of this template. |
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Click here to see/hide all the data network properties
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Off | Can be read to return if the device is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | On | |||||
Mode | Integer | Read Write
|
0 | Split | The mode of the Sorter, Split does alternate outputs, Filter decides output via Motherboard (Sorter), Logic determines output via parameter Output | |
1 | Filter | |||||
2 | Logic | |||||
Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
1 | Error | |||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Sorter. | |
1 | Locked | |||||
On | Integer | Read Write
|
0 | On | The current state of the Sorter. | |
1 | Off | |||||
RequiredPower | Integer | Read
|
||||
ClearMemory | Integer | Write
|
||||
ExportCount | Integer | Read
|
||||
ImportCount | Integer | Read
|
||||
Output | Integer | Read Write
|
-1 | Unset | In Logic mode, decides which side the next item will be sent to. (defaults to -1 after action) | |
0 | Straight | |||||
1 | Side | |||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|