Difference between revisions of "Filtration"
From Unofficial Stationeers Wiki
(Added info about where the outputs are located on the machine) |
(Add missing data outputs) |
||
Line 79: | Line 79: | ||
|- | |- | ||
| Power || Boolean || Returns whether the Filtration unit is turned on and receives power. (0 for no, 1 for yes) | | Power || Boolean || Returns whether the Filtration unit is turned on and receives power. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | Open || Boolean || Returns whether the Filtration unit IC Slot cover is open or closed. (0 for closed, 1 for open) | ||
+ | |- | ||
+ | | Mode || Boolean || Returns whether the Filtration unit is active or idle (0 for idle, 1 for Active) | ||
|- | |- | ||
| Error || Boolean || Returns whether the Filtration unit is flashing an error. (0 for no, 1 for yes) | | Error || Boolean || Returns whether the Filtration unit is flashing an error. (0 for no, 1 for yes) | ||
|- | |- | ||
| Lock || Boolean || Returns whether the Filtration unit is locked. (0 for no, 1 for yes) | | Lock || Boolean || Returns whether the Filtration unit is locked. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | Setting || Integer || | ||
+ | |- | ||
+ | | Maximum || Integer || | ||
+ | |- | ||
+ | | Ratio || Float || | ||
|- | |- | ||
| On || Boolean || Returns whether the Filtration unit is turned on. (0 for no, 1 for yes) | | On || Boolean || Returns whether the Filtration unit is turned on. (0 for no, 1 for yes) | ||
Line 88: | Line 98: | ||
| RequiredPower || Integer || Returns the current amount of power in Watts required by the Filtration unit. | | RequiredPower || Integer || Returns the current amount of power in Watts required by the Filtration unit. | ||
|- | |- | ||
− | | | + | | PressureInput|| Float || Input pressure in kilopascals |
+ | |- | ||
+ | | TemperatureInput || Float || Input temperature in kelvin | ||
+ | |- | ||
+ | | RatioOxygenInput || Float || Percentage of Oxygen in input as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioCarbonDioxidenInput || Float || Percentage of Carbon Dioxide in input as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioNitrogenInput || Float || Percentage of Nitrogen in input as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioPollutantInput || Float || Percentage of Pollutant in input as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioVolatilesInput || Float || Percentage of Volatiles in input as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioWaterInput || Float || Percentage of Water in input as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioNitrousOxideInput || Float || Percentage of Nitrous Oxide in input as ratio between 0 and 1 | ||
+ | |- | ||
+ | | TotalMolesInput|| Float || Total quantity of gas in input measured in moles | ||
+ | |- | ||
+ | | PressureOutput|| Float || Output pressure in kilopascals | ||
+ | |- | ||
+ | | TemperatureOutput || Float || Output temperature in kelvin | ||
+ | |- | ||
+ | | RatioOxygenOutput || Float || Percentage of Oxygen in output as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioCarbonDioxidenOutput || Float || Percentage of Carbon Dioxide in output as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioNitrogenOutput || Float || Percentage of Nitrogen in output as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioPollutantOutput || Float || Percentage of Pollutant in output as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioVolatilesOutput || Float || Percentage of Volatiles in output as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioWaterOutput || Float || Percentage of Water in output as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioNitrousOxideOutput || Float || Percentage of Nitrous Oxide in output as ratio between 0 and 1 | ||
+ | |- | ||
+ | | TotalMolesOutput|| Float || Total quantity of gas in output measured in moles | ||
+ | |- | ||
+ | | PressureOutput2|| Float || Waste pressure in kilopascals | ||
+ | |- | ||
+ | | TemperatureOutput2 || Float || Waste temperature in kelvin | ||
+ | |- | ||
+ | | RatioOxygenOutput2 || Float || Percentage of Oxygen in waste as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioCarbonDioxidenOutput2 || Float || Percentage of Carbon Dioxide in waste as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioNitrogenOutput2 || Float || Percentage of Nitrogen in waste as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioPollutantOutput2 || Float || Percentage of Pollutant in waste as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioVolatilesOutput2 || Float || Percentage of Volatiles in waste as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioWaterOutput2 || Float || Percentage of Water in waste as ratio between 0 and 1 | ||
+ | |- | ||
+ | | RatioNitrousOxideOutput2 || Float || Percentage of Nitrous Oxide in waste as ratio between 0 and 1 | ||
+ | |- | ||
+ | | TotalMolesOutput2 || Float || Total quantity of gas in waste measured in moles | ||
+ | |- | ||
+ | | CombustionInput || Float || | ||
+ | |- | ||
+ | | CombustionOutput || Float || | ||
+ | |- | ||
+ | | CombustionOutput2 || Float || | ||
|} | |} | ||
Revision as of 14:28, 30 July 2023
Operation | |
---|---|
Power Usage | 5w |
Construction | |
Placed with | Kit (Atmospherics) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Atmospherics) |
Contents
Description
Used to separate gasses from one pipe network into another using filters. Can filter up to two (2) gases at once. Guide (Filtration) provides additional information regarding the function, construction, and operation of a Filtration unit.
Usage
Once you have placed the Filtration Unit in your desired location, there are 3 separate connections that will need to be made:
- Input - Starting gas network that you want to filter from
- Output - Filtered gas
- Waste - Remaining unfiltered gas from the input
Place the appropriate filter(s) in the Filtration unit for the particular gas that your want to filter.
Be aware that the filtration unit unrealistically has an infinitely powerful pump integrated into its output port. That means as long as it is turned on and there is gas to filter out from the input it will pump that filtered out gas into the output pipe network (no matter how high the pressure in that output pipe network already is!). So eventually that pipe network will burst (around 60 MPa) unless you provide some sort of pop-off valve (e.g. a combination of a back-pressure regulator and a passive vent) or use a pipe analyzer and some logic to turn the filtration unit off when a certain amount of pressure is exceeded in the output pipe network. The filtration system can handle an input gas flow of just over 2.3L from a volume pump.
Characteristics
- It has a manual power switch.
- It consumes 10W of Power per Tick when idle and 44W when active.
- It has a separate Power Port and Data Port.
- It has a pipe port (labelled "Input") for the gas mixture from which the designated gas(es) will be filtered.
- It has a pipe port (labelled "Filtered") for the designated gas(es) that have been filtered. (This is in line with the input)
- It has a pipe port (labelled "Unfiltered") for any remaining unfiltered gases. (This is to the side)
- It can filter up to 2 different gases at once by inserting two different filters.
Note: When using an I/O slot reader chip, the filter slots are labeled as slot 1, slot 2 and slot 3(IC), with 1 being the slot closer to the inlet. When using an IC chip, the slots are labeled as slot 0, slot1 and slot 2(IC).
User Interface
A Filtration unit provides the following user interface:
Name | Type | Function |
---|---|---|
Filter (Right) | Slot 0 | Port for a gas filter. If gas of the same type is present in the incoming mixture, it will be redirected out the "Filtered" pipe port. |
Filter (Left) | Slot 1 | Another Port for a gas filter that functions the same as its twin slot. May contain the same or a different filter. |
v | Slot 2 | IC10 placed in filtration unit (has 2 Input/Outputs) |
On | Switch | Switches Filtration unit between turned on or turned off. (On=1/Off=0) |
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
On | Boolean | Powers on the Filtration unit on when set to 1. Powers off when set to 0. |
Open | Boolean | |
Setting | Integer | |
Lock | Boolean | |
Mode | Boolean | 0: idle, 1: Active |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Filtration unit is turned on and receives power. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Filtration unit IC Slot cover is open or closed. (0 for closed, 1 for open) |
Mode | Boolean | Returns whether the Filtration unit is active or idle (0 for idle, 1 for Active) |
Error | Boolean | Returns whether the Filtration unit is flashing an error. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Filtration unit is locked. (0 for no, 1 for yes) |
Setting | Integer | |
Maximum | Integer | |
Ratio | Float | |
On | Boolean | Returns whether the Filtration unit is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power in Watts required by the Filtration unit. |
PressureInput | Float | Input pressure in kilopascals |
TemperatureInput | Float | Input temperature in kelvin |
RatioOxygenInput | Float | Percentage of Oxygen in input as ratio between 0 and 1 |
RatioCarbonDioxidenInput | Float | Percentage of Carbon Dioxide in input as ratio between 0 and 1 |
RatioNitrogenInput | Float | Percentage of Nitrogen in input as ratio between 0 and 1 |
RatioPollutantInput | Float | Percentage of Pollutant in input as ratio between 0 and 1 |
RatioVolatilesInput | Float | Percentage of Volatiles in input as ratio between 0 and 1 |
RatioWaterInput | Float | Percentage of Water in input as ratio between 0 and 1 |
RatioNitrousOxideInput | Float | Percentage of Nitrous Oxide in input as ratio between 0 and 1 |
TotalMolesInput | Float | Total quantity of gas in input measured in moles |
PressureOutput | Float | Output pressure in kilopascals |
TemperatureOutput | Float | Output temperature in kelvin |
RatioOxygenOutput | Float | Percentage of Oxygen in output as ratio between 0 and 1 |
RatioCarbonDioxidenOutput | Float | Percentage of Carbon Dioxide in output as ratio between 0 and 1 |
RatioNitrogenOutput | Float | Percentage of Nitrogen in output as ratio between 0 and 1 |
RatioPollutantOutput | Float | Percentage of Pollutant in output as ratio between 0 and 1 |
RatioVolatilesOutput | Float | Percentage of Volatiles in output as ratio between 0 and 1 |
RatioWaterOutput | Float | Percentage of Water in output as ratio between 0 and 1 |
RatioNitrousOxideOutput | Float | Percentage of Nitrous Oxide in output as ratio between 0 and 1 |
TotalMolesOutput | Float | Total quantity of gas in output measured in moles |
PressureOutput2 | Float | Waste pressure in kilopascals |
TemperatureOutput2 | Float | Waste temperature in kelvin |
RatioOxygenOutput2 | Float | Percentage of Oxygen in waste as ratio between 0 and 1 |
RatioCarbonDioxidenOutput2 | Float | Percentage of Carbon Dioxide in waste as ratio between 0 and 1 |
RatioNitrogenOutput2 | Float | Percentage of Nitrogen in waste as ratio between 0 and 1 |
RatioPollutantOutput2 | Float | Percentage of Pollutant in waste as ratio between 0 and 1 |
RatioVolatilesOutput2 | Float | Percentage of Volatiles in waste as ratio between 0 and 1 |
RatioWaterOutput2 | Float | Percentage of Water in waste as ratio between 0 and 1 |
RatioNitrousOxideOutput2 | Float | Percentage of Nitrous Oxide in waste as ratio between 0 and 1 |
TotalMolesOutput2 | Float | Total quantity of gas in waste measured in moles |
CombustionInput | Float | |
CombustionOutput | Float | |
CombustionOutput2 | Float |
Slot Outputs
Slot 0 and 1 are the two gas filters. Slot 2 is the programmable chip
Output Name | Data Type | Description |
---|---|---|
Occupied | Boolean | Returns whether the slot is occupied. (0 for no, 1 for yes) |
OccupantHash | Integer | Returns the hash of the object in the slot. |
Quantity | Integer | Returns the current quantity, such as stack size, of the item in the slot. |
Damage | Integer | Returns the damage state of the item in the slot. |
Class | Integer | Returns an integer representing the class of object. |
MaxQuanity | Integer | Returns max stack size of the item in the slot. |
PrefabHash | Integer | Returns the hash of the structure in the slot. |