Difference between revisions of "Kit (Atmospherics) Filtration"
From Unofficial Stationeers Wiki
m |
|||
| Line 23: | Line 23: | ||
* It has a pipe port (labelled "Unfiltered") for any remaining unfiltered gases. | * It has a pipe port (labelled "Unfiltered") for any remaining unfiltered gases. | ||
* It can filter up to 2 different gases at once by inserting two different filters. | * It can filter up to 2 different gases at once by inserting two different filters. | ||
| − | Note: When using an I/O slot reader chip, the filter slots are labeled as slot 1 and slot | + | Note: When using an I/O slot reader chip, the filter slots are labeled as slot 1, slot 2 and slot 3(IC), with 1 being the slot closer to the inlet. |
| − | When using an IC chip, the slots are labeled as slot 0 and slot | + | When using an IC chip, the slots are labeled as slot 0, slot1 and slot 2(IC). |
==User Interface== | ==User Interface== | ||
| Line 32: | Line 32: | ||
! Name || Type !! Function | ! Name || Type !! Function | ||
|- | |- | ||
| − | | [[Filters|Filter]] (Right) || Slot || Port for a gas filter. If gas of the same type is present in the incoming mixture, it will be redirected out the "Filtered" pipe port. | + | | [[Filters|Filter]] (Right) || Slot 0 || Port for a gas filter. If gas of the same type is present in the incoming mixture, it will be redirected out the "Filtered" pipe port. |
|- | |- | ||
| − | | Filter (Left) || Slot || Another Port for a gas filter that functions the same as its twin slot. May contain the same or a different filter. | + | | Filter (Left) || Slot 1 || Another Port for a gas filter that functions the same as its twin slot. May contain the same or a different filter. |
|- | |- | ||
| − | | | + | | v || Slot 2 || IC10 placed in filtration unit (has 2 Input/Outputs) |
|- | |- | ||
| On || Switch || Switches Filtration unit between turned on or turned off. (On=1/Off=0) | | On || Switch || Switches Filtration unit between turned on or turned off. (On=1/Off=0) | ||
| Line 80: | Line 80: | ||
|} | |} | ||
| − | Slot Outputs | + | <!--T:6--> |
| + | ==Slot Outputs== | ||
| + | Slot0= Filter Left , Slot1= Filter Right , Slot2= Programmable Chip | ||
{| class="wikitable" | {| class="wikitable" | ||
| Line 101: | Line 103: | ||
|} | |} | ||
| − | <!--T: | + | <!--T:7--> |
==See Also== | ==See Also== | ||
* [[Guide (Filtration)]] | * [[Guide (Filtration)]] | ||
Revision as of 05:37, 21 March 2023
| Operation | |
|---|---|
| Power Usage | 5w |
| Construction | |
| Placed with | Kit (Atmospherics) |
| Placed on | Small Grid |
| Stage 1 | |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Kit (Atmospherics) |
Contents
Purpose
A Filtration unit is a powered Atmospheric processor used to filter specific gases from a mixture. Guide (Filtration) provides additional information regarding the function, construction, and operation of a Filtration unit.
Characteristics
- It has a manual power switch.
- It consumes 10W of Power per Tick when idle and 44W when active.
- It has a separate Power Port and Data Port.
- It has a pipe port (labelled "Input") for the gas mixture from which the designated gas(es) will be filtered.
- It has a pipe port (labelled "Filtered") for the designated gas(es) that have been filtered.
- It has a pipe port (labelled "Unfiltered") for any remaining unfiltered gases.
- It can filter up to 2 different gases at once by inserting two different filters.
Note: When using an I/O slot reader chip, the filter slots are labeled as slot 1, slot 2 and slot 3(IC), with 1 being the slot closer to the inlet. When using an IC chip, the slots are labeled as slot 0, slot1 and slot 2(IC).
User Interface
A Filtration unit provides the following user interface:
| Name | Type | Function |
|---|---|---|
| Filter (Right) | Slot 0 | Port for a gas filter. If gas of the same type is present in the incoming mixture, it will be redirected out the "Filtered" pipe port. |
| Filter (Left) | Slot 1 | Another Port for a gas filter that functions the same as its twin slot. May contain the same or a different filter. |
| v | Slot 2 | IC10 placed in filtration unit (has 2 Input/Outputs) |
| On | Switch | Switches Filtration unit between turned on or turned off. (On=1/Off=0) |
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
| Parameter Name | Data Type | Description |
|---|---|---|
| On | Boolean | Powers on the Filtration unit on when set to 1. Powers off when set to 0. |
| Open | Boolean | |
| Setting | Integer | |
| Lock | Boolean | |
| Mode | Boolean |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| Output Name | Data Type | Description |
|---|---|---|
| Power | Boolean | Returns whether the Filtration unit is turned on and receives power. (0 for no, 1 for yes) |
| Error | Boolean | Returns whether the Filtration unit is flashing an error. (0 for no, 1 for yes) |
| Lock | Boolean | Returns whether the Filtration unit is locked. (0 for no, 1 for yes) |
| On | Boolean | Returns whether the Filtration unit is turned on. (0 for no, 1 for yes) |
| RequiredPower | Integer | Returns the current amount of power in Watts required by the Filtration unit. |
| Quantity | Integer | Returns the current amount of Filter remaining. Slot 0 (Right), slot 1 (Left). |
Slot Outputs
Slot0= Filter Left , Slot1= Filter Right , Slot2= Programmable Chip
| Output Name | Data Type | Description |
|---|---|---|
| OccupantHash | Integer | Filter cartridge Hash-code (Identifier) |
| Occupied | Boolean | 0/1 filter slot empty/occupied |
| PrefabHash | Integer | |
| Quantity | Integer | Remaining life of filter cartridge. |
| Class | Integer | |
| Dammage | Integer | |
| MaxQuantity | Integer | Max. life of filter cartridge |
