* Casing is not insulated, will significantly heat up the surrounding environment. | * Casing is not insulated, will significantly heat up the surrounding environment. | ||
* Output is just like a furnace, superheated way beyond the max temperature a furnace may produce making it a perfect option for making furnace hot gasses. | * Output is just like a furnace, superheated way beyond the max temperature a furnace may produce making it a perfect option for making furnace hot gasses. | ||
− | * In one tick, if given a 2000L input network of fuel at 6MPa, will consume 350 mol of Fuel to output 253 Mol of Water at 7000 Celcius and 87 Mol of Co2+X at 4000 Celcius. | + | * In one tick, if given a 2000L input network of fuel at 6MPa, will consume 350 mol of Fuel to output 253 Mol of Water at '''7000''' Celcius and 87 Mol of Co2+X at 4000 Celcius. |
<!--T:3--> | <!--T:3--> |
Revision as of 02:07, 27 June 2022
Operation | |
---|---|
Power Usage | 20W+ |
Construction | |
Placed with | Kit (Atmospherics) |
Placed on | ? |
Stage 1 | |
Deconstruction | |
Deconstructed with | ? |
Item received | Kit (Atmospherics) |
Contents
Purpose
Burns a mix of volatiles and oxygen to create water.
It converts H2 and O2 to H2O at a conversion ratio of 2:1. More specifically, 2 mol H2 and 1 mol O2 will produce 1 mol H2O.
Characteristics
- Consumes up to 350 mol of Fuel per tick.
- Casing is not insulated, will significantly heat up the surrounding environment.
- Output is just like a furnace, superheated way beyond the max temperature a furnace may produce making it a perfect option for making furnace hot gasses.
- In one tick, if given a 2000L input network of fuel at 6MPa, will consume 350 mol of Fuel to output 253 Mol of Water at 7000 Celcius and 87 Mol of Co2+X at 4000 Celcius.
Notes
- Best not used indoors, output is incredibly difficult to cool down.
Logic
These are all the logic parameters of the device.
Parameter | Type | Access | Description |
---|---|---|---|
Activate | Boolean | Read/Write | 1 if a device is activated (usually meaning running), otherwise 0. |
On | Boolean | Read/Write | The current state of the device, 0 for off, 1 for on. |
RequiredPower | Float | Read-only | Idle operating power quantity, does not necessarily include extra demand power. |
Error | Boolean | Read-only | 1 if the device is in error state, otherwise 0. |
Power | Float | Read-only | Can be read to return if the device is correctly powered or not, set via power system, return 1 if powered and 0 if not. |
Setting | Integer | Read/Write | A variable setting that can be read or written, depending on the device. |
Lock | Boolean | Read/Write | 1 if a device is locked, otherwise 0, can be set in most devices and prevents the user from writing values. |
PrefabHash | Integer | Read-only | The hash of the structure. |
Maximum | Float | Read-only | Maximum setting of the device. |
Ratio | Float | Read-only | Context specific value depending on the device, 0 to based ratio. |