Difference between revisions of "Control Chair"
From Unofficial Stationeers Wiki
F1r3w4rr10r (talk | contribs) m (Add to Data Network category) |
F1r3w4rr10r (talk | contribs) (Update to use the new Structurebox syntax) |
||
Line 1: | Line 1: | ||
[[Category:Data Network]] | [[Category:Data Network]] | ||
− | {{ | + | {{Structurebox |
− | | name | + | | name = Control Chair |
− | | | + | | power_usage = 250W |
− | | | + | | placed_with_item = [[Kit (Furniture)]] |
− | | | + | | placed_on_grid = Small Grid |
+ | | decon_with_tool1 = [[Hand Drill]] | ||
+ | | item_rec1 = [[Kit (Furniture)]] | ||
}} | }} | ||
The '''Control Chair''' is a piece of furniture, which is constructed with the [[Kit (Furniture)]]. | The '''Control Chair''' is a piece of furniture, which is constructed with the [[Kit (Furniture)]]. |
Revision as of 16:07, 6 July 2018
Operation | |
---|---|
Power Usage | 250W |
Construction | |
Placed with | Kit (Furniture) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Furniture) |
The Control Chair is a piece of furniture, which is constructed with the Kit (Furniture).
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
Parameter Name | Data Type | Description |
---|---|---|
Mode | Integer | (Unknown) Accepts a range from 0 to 2. Affects the Mode output. |
Setting | Float | (Unknown) Accepts a range from 0.0 to 100.0. Affects the Setting output. |
On | Boolean | (Unknown) Supposedly turns the Control Chair on, when set to 1. Turns it off, when set to 0. Affects the On output. |
Data Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Control Chair is turned on and receives power. (0 for no, 1 for yes) |
Mode | Integer | (Unknown) Returns a range from 0 to 2. Is affected by the Mode parameter. |
Error | Boolean | Returns whether the Control Chair is flashing an error. |
Setting | Float | (Unknown) Returns a range from 0.0 to 100.0. Is affected by the Setting parameter. |
Maximum | Integer | (Unknown) Returns 100. |
Ratio | Float | Returns a range from 0.0 to 1.0. Returns the ratio of the set Setting to the Maximum. |
On | Boolean | Returns whether the Control Chair is turned on. (0 for no, 1 for yes) |
RequiredPower | Returns the power, currently needed by the Control Chair, in watts. |