Difference between revisions of "Carsten Milkau/Dual-Atmosphere Airlock"
From Unofficial Stationeers Wiki
< User:Carsten Milkau
(→Vent direction: Vent direction: equality comparison is a more straightforward explanation than a NOT gate) |
|||
(7 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
− | = | + | == Structure == |
− | == Constants == | + | == Piping == |
+ | |||
+ | == Electronics == | ||
+ | |||
+ | === Constants === | ||
* Zero | * Zero | ||
* "Vacuum" pressure | * "Vacuum" pressure | ||
− | == Target Atmosphere == | + | === Target Atmosphere === |
* [[Kit (Logic Switch)|Switch]] | * [[Kit (Logic Switch)|Switch]] | ||
− | * [[Carsten Milkau/RS-Latch]] | + | * [[User:Carsten Milkau/RS-Latch]] |
+ | |||
+ | === Current Atmosphere === | ||
+ | |||
+ | [[User:Carsten Milkau/D-Latch]] | ||
− | == | + | <pre>if (internal_pressure > vacuum_pressure) |
+ | then current_atmosphere = current_atmosphere | ||
+ | else current_atmosphere = target_atmosphere</pre> | ||
− | + | === Door sensor === | |
− | + | * <del>[[User:Carsten Milkau/OR Gate]]</del> | |
+ | * [[Kit (Logic I/O)#Batch Reader|Batch Reader]] | ||
+ | * [[User:Carsten Milkau/NOT Gate]] | ||
− | + | <pre>num_open_doors = read_sum(airlock_door open) | |
− | + | doors_closed = (num_open_doors = 0)</pre> | |
− | == Door control == | + | === Door control === |
if (my atmosphere) | if (my atmosphere) | ||
Line 26: | Line 38: | ||
else Zero | else Zero | ||
− | == Vent activation == | + | === Vent activation === |
if (my atmosphere) | if (my atmosphere) | ||
Line 32: | Line 44: | ||
else Zero | else Zero | ||
− | == Vent direction == | + | * atmosphere 0: max(atmosphere1, any door open) = Zero |
+ | * atmosphere 1: atmosphere1 > any door open | ||
+ | |||
+ | === Vent direction === | ||
+ | |||
+ | [[Kit (Logic Processor)#Compare Unit|Compare Unit]] | ||
− | + | <pre>if (my target atmosphere) | |
+ | then pressurize | ||
+ | else depressurize</pre> |
Latest revision as of 08:18, 22 July 2018
Contents
Structure[edit]
Piping[edit]
Electronics[edit]
Constants[edit]
- Zero
- "Vacuum" pressure
Target Atmosphere[edit]
Current Atmosphere[edit]
if (internal_pressure > vacuum_pressure) then current_atmosphere = current_atmosphere else current_atmosphere = target_atmosphere
Door sensor[edit]
num_open_doors = read_sum(airlock_door open) doors_closed = (num_open_doors = 0)
Door control[edit]
if (my atmosphere) then (internal pressure >= external pressure) else Zero
Vent activation[edit]
if (my atmosphere) then (doors closed) else Zero
- atmosphere 0: max(atmosphere1, any door open) = Zero
- atmosphere 1: atmosphere1 > any door open
Vent direction[edit]
if (my target atmosphere) then pressurize else depressurize