|
|
(67 intermediate revisions by 27 users not shown) |
Line 1: |
Line 1: |
− | [[Category:Atmospherics]]
| + | #REDIRECT [[Kit (Atmospherics)]] |
− | {{Itembox
| |
− | | name = Kit (Atmospherics)
| |
− | | image = [[File:ItemKitAtmospherics.png]]
| |
− | | createdwith = [[Hydraulic Pipe Bender]], [[Fabricator]]
| |
− | | cost = 10g [[Iron]], 5g [[Gold]], 20g [[Copper]]
| |
− | | stacks = no
| |
− | }}
| |
− | {{Structurebox
| |
− | | name = Atmospherics
| |
− | | image = [[File:Atmospherics front.jpg]]
| |
− | | placement = Small Grid
| |
− | | powerusage = 6000W
| |
− | }}
| |
− | =Air Conditioner Unit=
| |
− | ==Description==
| |
− | Used to lower and raise the temperature fed through it from the input pipe.<br>
| |
− | It has a range from -99 to 99 Celsius for the output
| |
− | | |
− | If the coolant pipe does not have 100kpa pressure it will divert output to coolant waste port to fill its coolant pipe
| |
− | | |
− | ==Usage==
| |
− | Place the Kit (Atmospherics) and run some pipes to the place you want to vent the heat. Place a few [[Pipe Radiator]]s on the pipe, fill it with whatever gas mixture you want.<br>
| |
− | Make a return loop on the coolant system back to the coolant waste port for a slightly better efficiency.<br>
| |
− | It will try to draw or expel heat to the coolant mix to make the input match the desired output.
| |
− | | |
− | == Logic Properties ==
| |
− | These are all logic properties of this device.
| |
− | | |
− | === Logic Parameters ===
| |
− | These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
| |
− | {| class="wikitable"
| |
− | |-
| |
− | ! Parameter Name !! Data Type !! Description
| |
− | |-
| |
− | | Open || (Unknown) || (Unknown) (This does not seem to influence the "Open" output.)
| |
− | |-
| |
− | | Mode || Integer || (Unknown) (Judging by the "Mode" output, it accepts values in the range 0-2.)
| |
− | |-
| |
− | | Lock || Boolean || Locks the Air Conditioner Unit, when set to 1. Unlocks it, when set to 0.
| |
− | |-
| |
− | | On || Boolean || Turns the Air Conditioner Unit on, when set to 1. Turns it off, when set to 0.
| |
− | |}
| |
− | | |
− | === Logic Outputs ===
| |
− | These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| |
− | {| class="wikitable"
| |
− | |-
| |
− | ! Output Name !! Data Type !! Description
| |
− | |-
| |
− | | Power || Boolean || Returns whether the Air Conditioner Unit is turned on. (0 is off, 1 is on) (Identical to "On" output. This might be intended to output whether the device is receiving power or not.)
| |
− | |-
| |
− | | Open || (Unknown) || (Unknown) (This does not seem to be influenced by the "Open" parameter.)
| |
− | |-
| |
− | | Mode || Integer || (Unknown) (Returns output in the range 0-2, equivalent to the input of the "Mode" parameter.)
| |
− | |-
| |
− | | Error || Boolean || Returns whether the Air Conditioner Unit is flashing an error. (0 when no error, 1 when flashing an error)
| |
− | |-
| |
− | | Lock || Boolean || Returns whether the Air Conditioner Unit is locked. (0 when not locked, 1 when locked)
| |
− | |-
| |
− | | On || Boolean || Returns whether the Air Conditioner Unit is turned on. (0 is off, 1 is on)
| |
− | |-
| |
− | | RequiredPower || Integer || Returns the amount of power the Air Conditioner Unit requires in Watts.
| |
− | |}
| |
− | | |
− | =Filtration Unit=
| |
− | ==Description==
| |
− | Used to filter out specific gasses and fluids from a mixture.<br>
| |
− | it can filter out up to 2 things at once
| |
− | | |
− | ==Usage==
| |
− | Place the Kit (Atmospherics) and change the variant to Filtration.<br>
| |
− | Place [[filter]]s in the machine for what you want to filter out.<br>
| |
− | There are three filtration pipe connections.<br>
| |
− | Filtration Input is where you connect the incoming atmosphere to be passed through the Filtration Atmospherics.<br>
| |
− | Filtration Waste is the remaining mix after extracting whatever the filters did.<br>
| |
− | Filtration Output is the filtered material for which you placed filters in the machine for.
| |
− | | |
− | == Logic Properties ==
| |
− | These are all logic properties of this device.
| |
− | | |
− | === Logic Parameters ===
| |
− | These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
| |
− | {| class="wikitable"
| |
− | |-
| |
− | ! Parameter Name !! Data Type !! Description
| |
− | |-
| |
− | | On || Boolean || Turns the Filtration Unit on, when set to 1. Turns it off, when set to 0.
| |
− | |}
| |
− | | |
− | === Logic Outputs ===
| |
− | These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| |
− | {| class="wikitable"
| |
− | |-
| |
− | ! Output Name !! Data Type !! Description
| |
− | |-
| |
− | | Power || Boolean || Returns whether the Filtration Unit is turned on. (0 is off, 1 is on) (Identical to "On" output. This might be intended to output whether the device is receiving power or not.)
| |
− | |-
| |
− | | Error || Boolean || Returns whether the Filtration Unit is flashing an error. (0 when no error, 1 when flashing an error)
| |
− | |-
| |
− | | On || Boolean || Returns whether the Filtration Unit is turned on. (0 is off, 1 is on)
| |
− | |-
| |
− | | RequiredPower || Integer || Returns the amount of power the Filtration Unit requires in Watts.
| |
− | |}
| |