Difference between revisions of "Active Vent"
From Unofficial Stationeers Wiki
(Added switch color of each mode) |
(description fix) |
||
(17 intermediate revisions by 8 users not shown) | |||
Line 4: | Line 4: | ||
[[Category:Atmospherics]] | [[Category:Atmospherics]] | ||
{{Itembox | {{Itembox | ||
− | + | | name = Kit (Active Vent) | |
− | + | | image = [[File:ItemActiveVent.png]] | |
− | + | | prefabhash = -842048328 | |
− | + | | prefabname = ItemActiveVent | |
− | + | | stacks = 5 | |
+ | | slot_class = SlotClass.None | ||
+ | | sorting_class = SortingClass.Kits | ||
+ | | recipe_machine1 = Hydraulic Pipe Bender | ||
+ | | recipe_cost1 = 5g [[Iron]], 1g [[Gold]], 5g [[Copper]] | ||
+ | | constructs = [[Active Vent]] | ||
}} | }} | ||
{{Structurebox | {{Structurebox | ||
− | + | | name = Active Vent | |
− | + | | image = [[File:StructureActiveVent.png]] | |
− | + | | prefab_hash = -1129453144 | |
− | + | | prefab_name = StructureActiveVent | |
− | + | | power_usage = 100W | |
− | + | | placed_on_grid = Small Grid | |
− | + | | decon_with_tool1 = [[Hand Drill]] | |
+ | | placed_with_item = [[Kit (Active Vent)]] | ||
+ | | item_rec1 = [[Kit (Active Vent)]] | ||
}} | }} | ||
== Description == <!--T:2--> | == Description == <!--T:2--> | ||
− | |||
− | |||
− | |||
− | "PressureExternal" | + | The Active Vent moves gas between the connected [[Pipe Network]] and the atmosphere surrounding the active vent. |
+ | It requires electric power to work (100 Watt). | ||
+ | |||
+ | The "PressureExternal" value is a measure of the atmosphere surrounding the active vent. | ||
+ | The "PressureInternal" value is a measure of the pressure inside the active vent pipe network. | ||
+ | |||
+ | Contrary to popular belief, both values are enforced, so the Active Vent comes with the functionality of a Pressure Regulator and simultaneously also Back Pressure Regulator. Note that setting these value and changing the Mode afterwards is ill-advised: Changing the Mode always resets both values to their defaults (101/0 for pumping into the room, 0/50 for pumping into the pipe), so they must be set (if at all) *after* setting the Mode. | ||
+ | |||
+ | * In "Outward mode" (switch is blue), the Active Vent increases the external pressure by moving gas from the pipe network to the surrounding atmosphere, up to "PressureExternal", but never allowing the pipe's pressure to drop below "PressureInternal". | ||
+ | * In "Inward mode" (switch is red), the Active Vent decreases the external pressure by moving gas from the surrounding atmosphere to the pipe network, down to "PressureExternal", never exceeding the pipe pressure set in "PressureInternal". | ||
+ | |||
+ | The "PressureExternal" value is set to 100 kPa when the [[Circuitboard (Airlock Control)|Circuitboard (Airlock Control)]] is used in a [[console|Console]]. This is the reason why the airlock is unable to pressurize when the atmosphere surrounding the active vent is unable to reach 100 kPa within the airlock. | ||
+ | |||
+ | The "PressureExternal" values can also be inconvenient on worlds like Loulan whose atmosphere is well above 101kPa. Manually-operated airlocks can not equalise the pressure within the airlock during the exit cycle to the Loulan atmosphere pressures. Without equal pressures you can not prevent wind currents from occurring when opening airlock doors. The active vent has no effect when the external pressure within the airlock surrounding the active vent is already >101kPa. When the pressure is <101kPa the vent will stop when it reaches 101kPa. | ||
+ | |||
+ | The "PressureExternal" and "PressureInternal" values can be modified using [[Kit (Logic I/O)|logic chips]] or programmatically via IC10 scripts. | ||
+ | |||
+ | '''Note''': These values reset to default values on mode change. Values can be set through logic chips, if the value is modified after a mode change. | ||
+ | |||
+ | '''Note''': Switching logic chips off then on will not modify values on the active vent, the values supplied to the chips must be altered for the values to be written. | ||
− | |||
To calculate the moles per tick, use the following equation: | To calculate the moles per tick, use the following equation: | ||
+ | |||
n = (P * V) / (R * T) | n = (P * V) / (R * T) | ||
− | |||
− | |||
− | |||
Where (Inward vent): | Where (Inward vent): | ||
− | * P = | + | * P = Room pressure (Min 10.1325 kPa) |
− | * V = 8000 | + | * V = 8000 litres |
* n = Moles per tick | * n = Moles per tick | ||
* R = Gas constant (8.3144) | * R = Gas constant (8.3144) | ||
Line 43: | Line 63: | ||
Where (Outward vent): | Where (Outward vent): | ||
− | * P = | + | * P = Pipe pressure (Min 10.1325 kPa) |
− | * V = Pipe volume in | + | * V = Pipe volume in litres |
* n = Moles per tick | * n = Moles per tick | ||
* R = Gas constant (8.3144) | * R = Gas constant (8.3144) | ||
* T = Pipe temperature | * T = Pipe temperature | ||
+ | |||
+ | (These do not take into account the constraints imposed by "PressureExternal" and "PressureInternal") | ||
+ | |||
+ | '''Note''': In order to get the proper units out of this calculation you need to use either kilopascal (kPa) and litre (l), or Pascal (Pa) and cubic meters (m<sup>3</sup>). | ||
'''Note''': The insert slot currently takes any item and seems to have no effect. | '''Note''': The insert slot currently takes any item and seems to have no effect. | ||
{{Data Network Header}} | {{Data Network Header}} | ||
− | |||
=== Mode Values === | === Mode Values === | ||
These lists the values and meanings for the "Mode" property of the Active Vent. | These lists the values and meanings for the "Mode" property of the Active Vent. | ||
{| class="wikitable" | {| class="wikitable" | ||
− | |- | + | |- |
− | ! Value !! Meaning | + | ! Value !! Meaning |
− | |- | + | |- |
− | | 0 || "Outward" mode ( | + | | 0 || "Outward" mode (Moves gas from the connected pipe network to the surrounding atmosphere.) |
− | |- | + | |- |
− | | 1 || "Inward" mode ( | + | | 1 || "Inward" mode (Moves gas from the surrounding atmosphere to the connected pipe network.) |
− | | | + | |} |
− | | 2 || ( | + | {{Data Parameters| |
− | |} | + | {{Data Parameters/row|Power|Boolean|w=0|Can be read to return if the device is correctly powered or not, set via the power system, return 1 if powered and 0 if not|multiple=2|0|Off|1|On}} |
+ | {{Data Parameters/row|Open|Integer|1 if device is open, otherwise 0}} | ||
+ | {{Data Parameters/row|Mode|Integer|The mode of the Active Vent.|multiple=2|0|Outward|1|Inward}} | ||
+ | {{Data Parameters/row|Error|Boolean|w=0|1 if device is in error state, otherwise 0|multiple=2|0|<p></p>|1|Error}} | ||
+ | {{Data Parameters/row|PressureExternal|Float|<div>"Outward" mode: Maximum pressure of the surrounding atmosphere. The default value is 101.325 (kPa)<br> | ||
+ | "Inward" mode": Minimum pressure of the surrounding atmosphere. The default value is 0 (kPa)</div>}} | ||
+ | {{Data Parameters/row|PressureInternal|Float|<div>"Outward" mode: Minimum pipe network pressure. The default value is 0 (kPa).<br> | ||
+ | "Inward" mode: Maximum pipe network pressure. The default value is 50662.5 (kPa).</div>}} | ||
+ | {{Data Parameters/row|Lock|Boolean|Disable manual operation of the Active Vent.|multiple=2|0|Unlocked|1|Locked}} | ||
+ | {{Data Parameters/row|Setting|Integer|A variable setting that can be read or written.}} | ||
+ | {{Data Parameters/row|Maximum|Integer|w=0|Maximum setting of the device}} | ||
+ | {{Data Parameters/row|Ratio|Float|w=0|Context specific value depending on device, 0 to 1 based ratio|0.0 to 1.0}} | ||
+ | {{Data Parameters/row|On|Boolean|The current state of the Active Vent.|multiple=2|0|Off|1|On}} | ||
+ | {{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}} | ||
+ | {{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}} | ||
+ | {{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}} | ||
+ | {{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32 bit integer.}} | ||
+ | }} | ||
− | + | '''Note''': The value of "PressureExternal" and "PressureInternal" will be reset to the default when changing modes. | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | '''Note''': If turned on, the vent will still consume energy when the target pressure is reached. | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
</translate> | </translate> |
Latest revision as of 07:19, 9 August 2024
Constructing Options | Active Vent |
---|---|
Properties | |
Stacks | Yes (5) |
Recipes | |
Hydraulic Pipe Bender | 5g Iron, 1g Gold, 5g Copper |
Logic | |
Item Hash | -842048328 |
Item Name | ItemActiveVent |
Logic Classes |
SlotClass.None SortingClass.Kits |
Operation | |
---|---|
Power Usage | 100W |
Prefab Hash | -1129453144 |
Prefab Name | StructureActiveVent |
Construction | |
Placed with | Kit (Active Vent) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Active Vent) |
Description[edit]
The Active Vent moves gas between the connected Pipe Network and the atmosphere surrounding the active vent. It requires electric power to work (100 Watt).
The "PressureExternal" value is a measure of the atmosphere surrounding the active vent. The "PressureInternal" value is a measure of the pressure inside the active vent pipe network.
Contrary to popular belief, both values are enforced, so the Active Vent comes with the functionality of a Pressure Regulator and simultaneously also Back Pressure Regulator. Note that setting these value and changing the Mode afterwards is ill-advised: Changing the Mode always resets both values to their defaults (101/0 for pumping into the room, 0/50 for pumping into the pipe), so they must be set (if at all) *after* setting the Mode.
- In "Outward mode" (switch is blue), the Active Vent increases the external pressure by moving gas from the pipe network to the surrounding atmosphere, up to "PressureExternal", but never allowing the pipe's pressure to drop below "PressureInternal".
- In "Inward mode" (switch is red), the Active Vent decreases the external pressure by moving gas from the surrounding atmosphere to the pipe network, down to "PressureExternal", never exceeding the pipe pressure set in "PressureInternal".
The "PressureExternal" value is set to 100 kPa when the Circuitboard (Airlock Control) is used in a Console. This is the reason why the airlock is unable to pressurize when the atmosphere surrounding the active vent is unable to reach 100 kPa within the airlock.
The "PressureExternal" values can also be inconvenient on worlds like Loulan whose atmosphere is well above 101kPa. Manually-operated airlocks can not equalise the pressure within the airlock during the exit cycle to the Loulan atmosphere pressures. Without equal pressures you can not prevent wind currents from occurring when opening airlock doors. The active vent has no effect when the external pressure within the airlock surrounding the active vent is already >101kPa. When the pressure is <101kPa the vent will stop when it reaches 101kPa.
The "PressureExternal" and "PressureInternal" values can be modified using logic chips or programmatically via IC10 scripts.
Note: These values reset to default values on mode change. Values can be set through logic chips, if the value is modified after a mode change.
Note: Switching logic chips off then on will not modify values on the active vent, the values supplied to the chips must be altered for the values to be written.
To calculate the moles per tick, use the following equation:
n = (P * V) / (R * T)
Where (Inward vent):
- P = Room pressure (Min 10.1325 kPa)
- V = 8000 litres
- n = Moles per tick
- R = Gas constant (8.3144)
- T = Room temperature
Where (Outward vent):
- P = Pipe pressure (Min 10.1325 kPa)
- V = Pipe volume in litres
- n = Moles per tick
- R = Gas constant (8.3144)
- T = Pipe temperature
(These do not take into account the constraints imposed by "PressureExternal" and "PressureInternal")
Note: In order to get the proper units out of this calculation you need to use either kilopascal (kPa) and litre (l), or Pascal (Pa) and cubic meters (m3).
Note: The insert slot currently takes any item and seems to have no effect.
Data Network Properties[edit]
These are all Data Network properties of this device.
Mode Values[edit]
These lists the values and meanings for the "Mode" property of the Active Vent.
Value | Meaning |
---|---|
0 | "Outward" mode (Moves gas from the connected pipe network to the surrounding atmosphere.) |
1 | "Inward" mode (Moves gas from the surrounding atmosphere to the connected pipe network.) |
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Off | Can be read to return if the device is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | On | |||||
Open | Integer | Read Write
|
||||
Mode | Integer | Read Write
|
0 | Outward | The mode of the Active Vent. | |
1 | Inward | |||||
Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
1 | Error | |||||
PressureExternal | Float | Read Write
|
||||
PressureInternal | Float | Read Write
|
||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Active Vent. | |
1 | Locked | |||||
Setting | Integer | Read Write
|
||||
Maximum | Integer | Read
|
||||
Ratio | Float | Read
|
0.0 to 1.0 | |||
On | Boolean | Read Write
|
0 | Off | The current state of the Active Vent. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|
Note: The value of "PressureExternal" and "PressureInternal" will be reset to the default when changing modes.
Note: If turned on, the vent will still consume energy when the target pressure is reached.