Toggle menu
Toggle preferences menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

Talk:Portables Connector: Difference between revisions

Discussion page of Portables Connector
Legolegs (talk | contribs)
has is an internal volume?
 
Legolegs (talk | contribs)
ty
 
(One intermediate revision by one other user not shown)
Line 1: Line 1:
It appears to me that the Portables Connector has no internal volume. Where that 100L number came from? I'm seeing it for long time everywhere. [[User:Legolegs|Legolegs]] ([[User talk:Legolegs|talk]]) 12:53, 28 March 2026 (UTC)
It appears to me that the Portables Connector has no internal volume. Where that 100L number came from? I'm seeing it for long time everywhere. [[User:Legolegs|Legolegs]] ([[User talk:Legolegs|talk]]) 12:53, 28 March 2026 (UTC)
-----
:Not sure, could be an older implementation of it.
:Its code running every atmospherics tick checks if there's a ''PortableAtmospherics'' implementer in its tank slot.
:If not, it aborts early without doing anything.
:If it does, it checks if there's a gas pipe connected and not waiting for a blocking atmospheric event to complete. If it passes that :check, it mixes gas contents betwen the gas pipe network and the PortableAtmospherics's internal atmosphere.
:Then it does the same check, but with the liquid pipe and liquid contents.
:There's no 100 involved anywhere, not even in the ''StructurePortablesConnector'' prefab. Maybe one of the PortableAtmospherics implementers had a 100L volume at some point.
:I'd say removing references to the portables connector having a 100L volume should be safe now.
:-[[User:RA2lover|RA2lover]] ([[User talk:RA2lover|talk]]) 21:09, 28 March 2026 (UTC)
-----
::Thank you for the clarification. I did the edits. [[User:Legolegs|Legolegs]] ([[User talk:Legolegs|talk]]) 10:39, 29 March 2026 (UTC)

Latest revision as of 10:39, 29 March 2026

It appears to me that the Portables Connector has no internal volume. Where that 100L number came from? I'm seeing it for long time everywhere. Legolegs (talk) 12:53, 28 March 2026 (UTC)


Not sure, could be an older implementation of it.
Its code running every atmospherics tick checks if there's a PortableAtmospherics implementer in its tank slot.
If not, it aborts early without doing anything.
If it does, it checks if there's a gas pipe connected and not waiting for a blocking atmospheric event to complete. If it passes that :check, it mixes gas contents betwen the gas pipe network and the PortableAtmospherics's internal atmosphere.
Then it does the same check, but with the liquid pipe and liquid contents.
There's no 100 involved anywhere, not even in the StructurePortablesConnector prefab. Maybe one of the PortableAtmospherics implementers had a 100L volume at some point.
I'd say removing references to the portables connector having a 100L volume should be safe now.
-RA2lover (talk) 21:09, 28 March 2026 (UTC)

Thank you for the clarification. I did the edits. Legolegs (talk) 10:39, 29 March 2026 (UTC)