Actions

Difference between revisions of "Filtration"

From Unofficial Stationeers Wiki

(Didn't know this page existed... In hindsight, maybe this redirect should be removed and Kit (Atmospherics) Filtration renamed to "Filtration". Same for the other atmospherics devices)
(corrected typo.)
 
(18 intermediate revisions by 10 users not shown)
Line 1: Line 1:
#REDIRECT [[Kit (Atmospherics) Filtration]]
+
[[Category:Atmospherics]]
 +
<languages/>
 +
<translate>
 +
{{Structurebox
 +
| name            = Filtration
 +
| image            = [[File:filtration.jpg]]
 +
| prefab_hash      = -348054045
 +
| power_usage      = 5w
 +
| placed_with_item = [[Kit (Atmospherics)]]
 +
| placed_on_grid  = Small Grid
 +
 
 +
| const_with_item1 = 2 x [[Kit (Pipe)]]
 +
| decon_with_tool1 = [[Hand Drill]]
 +
| item_rec1        = [[Kit (Atmospherics)]]
 +
 
 +
| const_with_tool2 = [[Screwdriver]]
 +
| const_with_item2 = [[Cable Coil]]
 +
| decon_with_tool2 = [[Wrench]]
 +
 
 +
| decon_with_tool3 = [[Hand Drill]]
 +
}}
 +
<!--T:1-->
 +
=Description=
 +
Filtration Unit is a powered machine, that is used to separate [[Gas|gases]] from one [[Pipes|pipe]] network into another using [[Filter|filters]]. Identical to most other machines deployable from the [[Kit (Atmospherics)]], Filtration unit occupies a 2x1 space on the small building grid supported by a frame. Back face of the unit provide floor-level power and logic cable ports, while the front side holds the control panel and two filter sockets. Front and either side also feature dedicated one-way pipe slots for managing gas inputs and ouputs.
 +
 
 +
=Usage=
 +
Once you have placed the Filtration Unit in your desired location, there are 3 separate pipe connections that will need to be made:
 +
# '''Input''' - Starting gas network that you want to filter from, right of the front panel.
 +
# '''Output 1''' - Filtered gas output, left of the front panel.
 +
# '''Output 2''' - The remainder gas mixture output, colloquially called "waste output", below the front panel and to the side of the inline between the two primary connections.
 +
<br>
 +
When powered and turned on, Filtration Unit will take a specific amount (in mols) of the Input gas mixture and process it using the Filters attached. It will then separate all the gases associated with these Filters and eject them to the Output 1 pipe network, and eject the remaining gases to the Output 2 network. Filtration Unit can process greater amount of gas over time if the Input network pressure is significantly greater than pressure in either of its ouput networks.
 +
<br>
 +
[[Guide (Filtration)]] provides additional information regarding the function, construction, and operation of a Filtration unit.
 +
 
 +
=Characteristics=
 +
* It has a manual power switch.
 +
* It consumes 10W of [[Power]] per [[Tick]] when idle and 44W when active.
 +
* It has a separate [[Power Port]] and [[Data Port]].
 +
* It has an on-board IC10 chip slot.
 +
* It has a pipe port (labelled "Input") for the gas mixture from which the designated gas(es) '''will be''' filtered.
 +
* It has a pipe port (labelled "Filtered") for the designated gas(es) that '''have been''' filtered. (This is in line with and directly opposite of the input)
 +
* It has a pipe port (labelled "Unfiltered") for any remaining unfiltered gases. (This is to the side)
 +
* It can filter up to 2 different gases at once by inserting two different filters.
 +
** Inserting two of the '''same''' type of filter does not increase filtration speed.
 +
Note: When using an I/O slot reader chip, the filter slots are labeled as slot 1, slot 2 and slot 3(IC), with 1 being the slot closer to the inlet.
 +
When using an IC chip, the slots are labeled as slot 0, slot1 and slot 2(IC).
 +
 
 +
=User Interface=
 +
A Filtration unit provides the following user interface:
 +
{| class="wikitable"
 +
|-
 +
! Name || Type !! Function
 +
|-
 +
| [[Filters|Filter]] (Right) || Slot 0 || Port for a gas filter. If gas of the same type is present in the incoming mixture, it will be redirected out the "Filtered" pipe port.
 +
|-
 +
| Filter (Left) || Slot 1 || Another Port for a gas filter that functions the same as its twin slot. May contain the same or a different filter.
 +
|-
 +
| v || Slot 2 || IC10 placed in filtration unit (has 2 Input/Outputs)
 +
|-
 +
| On || Switch || Switches Filtration unit between turned on or turned off. (On=1/Off=0)
 +
|-
 +
|}
 +
 
 +
{{Data Network Header}}
 +
 
 +
{{Data Parameters}}
 +
<!--T:4-->
 +
{| class="wikitable"
 +
|-
 +
! Parameter Name !! Data Type !! Description
 +
|-
 +
| On || Boolean || Powers on the Filtration unit on when set to 1. Powers off when set to 0.
 +
|-
 +
| Open || Boolean  ||
 +
|-
 +
| Setting || Integer ||
 +
|-
 +
| Lock || Boolean ||
 +
|-
 +
| Mode || Boolean  || 0: idle, 1: Active
 +
|}
 +
 
 +
{{Data Outputs}}
 +
<!--T:5-->
 +
{| class="wikitable"
 +
|-
 +
! Output Name !! Data Type !! Description
 +
|-
 +
| Power || Boolean || Returns whether the Filtration unit is turned on and receives power. (0 for no, 1 for yes)
 +
|-
 +
| Open || Boolean  || Returns whether the Filtration unit IC Slot cover is open or closed. (0 for closed, 1 for open)
 +
|-
 +
| Mode || Boolean  || Returns whether the Filtration unit is active or idle (0 for idle, 1 for Active)
 +
|-
 +
| Error || Boolean || Returns whether the Filtration unit is flashing an error. (0 for no, 1 for yes)
 +
|-
 +
| Lock || Boolean || Returns whether the Filtration unit is locked. (0 for no, 1 for yes)
 +
|-
 +
| Setting || Integer ||
 +
|-
 +
| Maximum || Integer ||
 +
|-
 +
| Ratio || Float ||
 +
|-
 +
| On || Boolean || Returns whether the Filtration unit is turned on. (0 for no, 1 for yes)
 +
|-
 +
| RequiredPower || Integer || Returns the current amount of power in Watts required by the Filtration unit.
 +
|-
 +
| PressureInput|| Float || Input pressure in kilopascals
 +
|-
 +
| TemperatureInput || Float || Input temperature in kelvin
 +
|-
 +
| RatioOxygenInput || Float || Percentage of Oxygen in input as ratio between 0 and 1
 +
|-
 +
| RatioCarbonDioxideInput || Float || Percentage of Carbon Dioxide in input as ratio between 0 and 1
 +
|-
 +
| RatioNitrogenInput || Float || Percentage of Nitrogen in input as ratio between 0 and 1
 +
|-
 +
| RatioPollutantInput || Float || Percentage of Pollutant in input as ratio between 0 and 1
 +
|-
 +
| RatioVolatilesInput || Float || Percentage of Volatiles in input as ratio between 0 and 1
 +
|-
 +
| RatioWaterInput || Float || Percentage of Water in input as ratio between 0 and 1
 +
|-
 +
| RatioNitrousOxideInput || Float || Percentage of Nitrous Oxide in input as ratio between 0 and 1
 +
|-
 +
| TotalMolesInput|| Float || Total quantity of gas in input measured in moles
 +
|-
 +
| PressureOutput|| Float || Output pressure in kilopascals
 +
|-
 +
| TemperatureOutput || Float || Output temperature in kelvin
 +
|-
 +
| RatioOxygenOutput || Float || Percentage of Oxygen in output as ratio between 0 and 1
 +
|-
 +
| RatioCarbonDioxideOutput || Float || Percentage of Carbon Dioxide in output as ratio between 0 and 1
 +
|-
 +
| RatioNitrogenOutput || Float || Percentage of Nitrogen in output as ratio between 0 and 1
 +
|-
 +
| RatioPollutantOutput || Float || Percentage of Pollutant in output as ratio between 0 and 1
 +
|-
 +
| RatioVolatilesOutput || Float || Percentage of Volatiles in output as ratio between 0 and 1
 +
|-
 +
| RatioWaterOutput || Float || Percentage of Water in output as ratio between 0 and 1
 +
|-
 +
| RatioNitrousOxideOutput || Float || Percentage of Nitrous Oxide in output as ratio between 0 and 1
 +
|-
 +
| TotalMolesOutput|| Float || Total quantity of gas in output measured in moles
 +
|-
 +
| PressureOutput2|| Float || Waste pressure in kilopascals
 +
|-
 +
| TemperatureOutput2 || Float || Waste temperature in kelvin
 +
|-
 +
| RatioOxygenOutput2 || Float || Percentage of Oxygen in waste as ratio between 0 and 1
 +
|-
 +
| RatioCarbonDioxideOutput2 || Float || Percentage of Carbon Dioxide in waste as ratio between 0 and 1
 +
|-
 +
| RatioNitrogenOutput2 || Float || Percentage of Nitrogen in waste as ratio between 0 and 1
 +
|-
 +
| RatioPollutantOutput2 || Float || Percentage of Pollutant in waste as ratio between 0 and 1
 +
|-
 +
| RatioVolatilesOutput2 || Float || Percentage of Volatiles in waste as ratio between 0 and 1
 +
|-
 +
| RatioWaterOutput2 || Float || Percentage of Water in waste as ratio between 0 and 1
 +
|-
 +
| RatioNitrousOxideOutput2 || Float || Percentage of Nitrous Oxide in waste as ratio between 0 and 1
 +
|-
 +
| TotalMolesOutput2 || Float || Total quantity of gas in waste measured in moles
 +
|-
 +
| CombustionInput || Float ||
 +
|-
 +
| CombustionOutput || Float ||
 +
|-
 +
| CombustionOutput2 || Float ||
 +
|}
 +
 
 +
<!--T:6-->
 +
==Slot Outputs==
 +
Slot 0 and 1 are the two gas [[filter]]s.  Slot 2 is the [[Integrated Circuit (IC10)|programmable chip]]
 +
{| class="wikitable"
 +
|-
 +
! Output Name !! Data Type !! Description
 +
|-
 +
| Occupied || Boolean || Returns whether the slot is occupied. (0 for no, 1 for yes)
 +
|-
 +
| OccupantHash || Integer || Returns the hash of the object in the slot.
 +
|-
 +
| Quantity || Integer || Returns the filter life remaining, in percent.
 +
|-
 +
| Damage || Integer || Returns the damage state of the item in the slot.
 +
|-
 +
| Class || Integer || Returns an integer representing the class of object.
 +
|-
 +
| MaxQuanity || Integer || Returns max stack size of the item in the slot.
 +
|-
 +
| PrefabHash || Integer || Returns the hash of the structure in the slot.
 +
|}
 +
 
 +
<!--T:7-->
 +
=See Also=
 +
* [[Guide (Filtration)]]
 +
* [[Kit (Atmospherics)]]
 +
* [[Kit (Portable Scrubber) Portable Scrubber|Portable Scrubber]]
 +
</translate>

Latest revision as of 10:08, 16 November 2025


Filtration
Filtration.jpg
Operation
Power Usage 5w
Prefab Hash -348054045
Construction
Placed with Kit (Atmospherics)
Placed on Small Grid
Stage 1
Next Stage Construction
Constructed with item 2 x Kit (Pipe)
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Atmospherics)
Stage 2
Next Stage Construction
Constructed with tool Screwdriver
Constructed with item Cable Coil
Deconstruction
Deconstructed with Wrench
Stage 3
Deconstruction
Deconstructed with Hand Drill

Description[edit]

Filtration Unit is a powered machine, that is used to separate gases from one pipe network into another using filters. Identical to most other machines deployable from the Kit (Atmospherics), Filtration unit occupies a 2x1 space on the small building grid supported by a frame. Back face of the unit provide floor-level power and logic cable ports, while the front side holds the control panel and two filter sockets. Front and either side also feature dedicated one-way pipe slots for managing gas inputs and ouputs.

Usage[edit]

Once you have placed the Filtration Unit in your desired location, there are 3 separate pipe connections that will need to be made:

  1. Input - Starting gas network that you want to filter from, right of the front panel.
  2. Output 1 - Filtered gas output, left of the front panel.
  3. Output 2 - The remainder gas mixture output, colloquially called "waste output", below the front panel and to the side of the inline between the two primary connections.


When powered and turned on, Filtration Unit will take a specific amount (in mols) of the Input gas mixture and process it using the Filters attached. It will then separate all the gases associated with these Filters and eject them to the Output 1 pipe network, and eject the remaining gases to the Output 2 network. Filtration Unit can process greater amount of gas over time if the Input network pressure is significantly greater than pressure in either of its ouput networks.
Guide (Filtration) provides additional information regarding the function, construction, and operation of a Filtration unit.

Characteristics[edit]

  • It has a manual power switch.
  • It consumes 10W of Power per Tick when idle and 44W when active.
  • It has a separate Power Port and Data Port.
  • It has an on-board IC10 chip slot.
  • It has a pipe port (labelled "Input") for the gas mixture from which the designated gas(es) will be filtered.
  • It has a pipe port (labelled "Filtered") for the designated gas(es) that have been filtered. (This is in line with and directly opposite of the input)
  • It has a pipe port (labelled "Unfiltered") for any remaining unfiltered gases. (This is to the side)
  • It can filter up to 2 different gases at once by inserting two different filters.
    • Inserting two of the same type of filter does not increase filtration speed.

Note: When using an I/O slot reader chip, the filter slots are labeled as slot 1, slot 2 and slot 3(IC), with 1 being the slot closer to the inlet. When using an IC chip, the slots are labeled as slot 0, slot1 and slot 2(IC).

User Interface[edit]

A Filtration unit provides the following user interface:

Name Type Function
Filter (Right) Slot 0 Port for a gas filter. If gas of the same type is present in the incoming mixture, it will be redirected out the "Filtered" pipe port.
Filter (Left) Slot 1 Another Port for a gas filter that functions the same as its twin slot. May contain the same or a different filter.
v Slot 2 IC10 placed in filtration unit (has 2 Input/Outputs)
On Switch Switches Filtration unit between turned on or turned off. (On=1/Off=0)

Data Network Properties[edit]

These are all Data Network properties of this device.

Data Parameters[edit]

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
On Boolean Powers on the Filtration unit on when set to 1. Powers off when set to 0.
Open Boolean
Setting Integer
Lock Boolean
Mode Boolean 0: idle, 1: Active

Data Outputs[edit]

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Filtration unit is turned on and receives power. (0 for no, 1 for yes)
Open Boolean Returns whether the Filtration unit IC Slot cover is open or closed. (0 for closed, 1 for open)
Mode Boolean Returns whether the Filtration unit is active or idle (0 for idle, 1 for Active)
Error Boolean Returns whether the Filtration unit is flashing an error. (0 for no, 1 for yes)
Lock Boolean Returns whether the Filtration unit is locked. (0 for no, 1 for yes)
Setting Integer
Maximum Integer
Ratio Float
On Boolean Returns whether the Filtration unit is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power in Watts required by the Filtration unit.
PressureInput Float Input pressure in kilopascals
TemperatureInput Float Input temperature in kelvin
RatioOxygenInput Float Percentage of Oxygen in input as ratio between 0 and 1
RatioCarbonDioxideInput Float Percentage of Carbon Dioxide in input as ratio between 0 and 1
RatioNitrogenInput Float Percentage of Nitrogen in input as ratio between 0 and 1
RatioPollutantInput Float Percentage of Pollutant in input as ratio between 0 and 1
RatioVolatilesInput Float Percentage of Volatiles in input as ratio between 0 and 1
RatioWaterInput Float Percentage of Water in input as ratio between 0 and 1
RatioNitrousOxideInput Float Percentage of Nitrous Oxide in input as ratio between 0 and 1
TotalMolesInput Float Total quantity of gas in input measured in moles
PressureOutput Float Output pressure in kilopascals
TemperatureOutput Float Output temperature in kelvin
RatioOxygenOutput Float Percentage of Oxygen in output as ratio between 0 and 1
RatioCarbonDioxideOutput Float Percentage of Carbon Dioxide in output as ratio between 0 and 1
RatioNitrogenOutput Float Percentage of Nitrogen in output as ratio between 0 and 1
RatioPollutantOutput Float Percentage of Pollutant in output as ratio between 0 and 1
RatioVolatilesOutput Float Percentage of Volatiles in output as ratio between 0 and 1
RatioWaterOutput Float Percentage of Water in output as ratio between 0 and 1
RatioNitrousOxideOutput Float Percentage of Nitrous Oxide in output as ratio between 0 and 1
TotalMolesOutput Float Total quantity of gas in output measured in moles
PressureOutput2 Float Waste pressure in kilopascals
TemperatureOutput2 Float Waste temperature in kelvin
RatioOxygenOutput2 Float Percentage of Oxygen in waste as ratio between 0 and 1
RatioCarbonDioxideOutput2 Float Percentage of Carbon Dioxide in waste as ratio between 0 and 1
RatioNitrogenOutput2 Float Percentage of Nitrogen in waste as ratio between 0 and 1
RatioPollutantOutput2 Float Percentage of Pollutant in waste as ratio between 0 and 1
RatioVolatilesOutput2 Float Percentage of Volatiles in waste as ratio between 0 and 1
RatioWaterOutput2 Float Percentage of Water in waste as ratio between 0 and 1
RatioNitrousOxideOutput2 Float Percentage of Nitrous Oxide in waste as ratio between 0 and 1
TotalMolesOutput2 Float Total quantity of gas in waste measured in moles
CombustionInput Float
CombustionOutput Float
CombustionOutput2 Float

Slot Outputs[edit]

Slot 0 and 1 are the two gas filters. Slot 2 is the programmable chip

Output Name Data Type Description
Occupied Boolean Returns whether the slot is occupied. (0 for no, 1 for yes)
OccupantHash Integer Returns the hash of the object in the slot.
Quantity Integer Returns the filter life remaining, in percent.
Damage Integer Returns the damage state of the item in the slot.
Class Integer Returns an integer representing the class of object.
MaxQuanity Integer Returns max stack size of the item in the slot.
PrefabHash Integer Returns the hash of the structure in the slot.

See Also[edit]