Difference between revisions of "Pressurant Valve"
From Unofficial Stationeers Wiki
(Created page with "<translate> <!--T:1--> {{Itembox | name = Condensation Valve | image = File:Pressurant Valve.png }} ==Description== <!--T:2--> <!--T:3--> Pumps gas into...") |
|||
| (4 intermediate revisions by 2 users not shown) | |||
| Line 1: | Line 1: | ||
| − | <translate> | + | <noinclude><translate></noinclude> |
<!--T:1--> | <!--T:1--> | ||
| − | {{ | + | {{Structurebox |
| − | + | | name = Pressurant Valve | |
| − | + | | image = [[File:Pressurant Valve.png]] | |
| + | | prefab_hash = 23052817 | ||
| + | | prefab_name = StructurePressurantValve | ||
| + | | power_usage = 100W | ||
| + | | placed_on_grid = Small Grid | ||
| + | | decon_with_tool1 = [[Hand Drill]] | ||
| + | | placed_with_item = [[Kit (Pressure Regulator)]] | ||
| + | | item_rec1 = [[Kit (Pressure Regulator)]] | ||
}} | }} | ||
| − | |||
==Description== <!--T:2--> | ==Description== <!--T:2--> | ||
| + | <blockquote><q>Pumps gas into a liquid pipe in order to raise the pressure</q><br> | ||
| + | '''- Stationpedia'''</blockquote> | ||
<!--T:3--> | <!--T:3--> | ||
| − | |||
| − | |||
| − | |||
| − | </translate> | + | The Pressurant Valve is an active powered device for controlled transfer of substances between the two pipe networks. When active, Pressurant Valve will pump the gas from Input pipe network into the Output liquid pipe network until the target pressure defined by the valve setting is reached or exceeded, or unless the input pipe runs dry. When being placed, hologram indicators will display the Input pipe arrow inward, the Output pipe arrow outward, and the power socket on its side. It has a pressure control valve, which defines the target pressure. |
| + | |||
| + | Pressurant Valve is conventionally used for maintaining the liquid state of a contained substance (such as [[water]]), that would otherwise evaporate in absense of the background pressure. It can also be utilized to actively condense a cooled gas into a liquid by injecting a pressurant gas, or inversely to force the liquid to evaporate by injecting a heated gas and raising the temperature without the dedicated [[Pipe Heater (Liquid)]]. The more efficient use of these principles require the knowledge of the [[gas]] phase change diagram, to pick an appropriate gas input, its temperature, and the target pressure, the combination of which achieves the desired final result. | ||
| + | |||
| + | {{Data Network Header}} | ||
| + | {{Data Parameters| | ||
| + | {{Data Parameters/row|Power|Boolean|w=0|Can be read to return if the Pressurant Valve is correctly powered or not, set via the power system, return 1 if powered and 0 if not|multiple=2|0|Unpowered|1|Powered}} | ||
| + | {{Data Parameters/row|Error|Boolean|w=0|1 if device is in error state, otherwise 0|multiple=2|0|<p></p>|1|Error}} | ||
| + | {{Data Parameters/row|Lock|Boolean|Disable manual operation of the Pressurant Valve.|multiple=2|0|Unlocked|1|Locked}} | ||
| + | {{Data Parameters/row|Setting|Integer|A variable setting that can be read or written.|0.0 to 60795.0}} | ||
| + | {{Data Parameters/row|Maximum|Float|w=0|Maximum setting of the Pressurant Valve}} | ||
| + | {{Data Parameters/row|Ratio|Float|w=0|Context specific value depending on device, 0 to 1 based ratio|0.0 to 1.0}} | ||
| + | {{Data Parameters/row|On|Boolean|The current state of the Pressurant Valve.|multiple=2|0|Off|1|On}} | ||
| + | {{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}} | ||
| + | {{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}} | ||
| + | {{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}} | ||
| + | {{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32 bit integer.}} | ||
| + | }} | ||
| + | |||
| + | <noinclude></translate></noinclude> | ||
| + | |||
[[Category:Atmospherics]] | [[Category:Atmospherics]] | ||
Latest revision as of 13:53, 18 May 2025
![]() | |
| Operation | |
|---|---|
| Power Usage | 100W |
| Prefab Hash | 23052817 |
| Prefab Name | StructurePressurantValve |
| Construction | |
| Placed with | Kit (Pressure Regulator) |
| Placed on | Small Grid |
| Stage 1 | |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Kit (Pressure Regulator) |
Description[edit]
Pumps gas into a liquid pipe in order to raise the pressure
- Stationpedia
The Pressurant Valve is an active powered device for controlled transfer of substances between the two pipe networks. When active, Pressurant Valve will pump the gas from Input pipe network into the Output liquid pipe network until the target pressure defined by the valve setting is reached or exceeded, or unless the input pipe runs dry. When being placed, hologram indicators will display the Input pipe arrow inward, the Output pipe arrow outward, and the power socket on its side. It has a pressure control valve, which defines the target pressure.
Pressurant Valve is conventionally used for maintaining the liquid state of a contained substance (such as water), that would otherwise evaporate in absense of the background pressure. It can also be utilized to actively condense a cooled gas into a liquid by injecting a pressurant gas, or inversely to force the liquid to evaporate by injecting a heated gas and raising the temperature without the dedicated Pipe Heater (Liquid). The more efficient use of these principles require the knowledge of the gas phase change diagram, to pick an appropriate gas input, its temperature, and the target pressure, the combination of which achieves the desired final result.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
| Parameter Name | Data Type | Access | Value | Description | ||
|---|---|---|---|---|---|---|
| Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Pressurant Valve is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
| 1 | Powered | |||||
| Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
| 1 | Error | |||||
| Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Pressurant Valve. | |
| 1 | Locked | |||||
| Setting | Integer | Read Write
|
0.0 to 60795.0 | |||
| Maximum | Float | Read
|
||||
| Ratio | Float | Read
|
0.0 to 1.0 | |||
| On | Boolean | Read Write
|
0 | Off | The current state of the Pressurant Valve. | |
| 1 | On | |||||
| RequiredPower | Integer | Read
|
||||
| PrefabHash | Integer | Read
|
||||
| ReferenceId | Integer | Read
|
||||
| NameHash | Integer | Read
|
||||

