Actions

Difference between revisions of "Back Pressure Regulator"

From Unofficial Stationeers Wiki

(rework back pressure regulator page)
(Description)
 
(2 intermediate revisions by one other user not shown)
Line 1: Line 1:
[[Category:Atmospherics]]
 
 
{{Structurebox
 
{{Structurebox
 
| name = Back Pressure Regulator
 
| name = Back Pressure Regulator
Line 14: Line 13:
 
<blockquote><q>Unlike the [[Pressure Regulator]], which closes when the input exceeds a given pressure, the back pressure regulator opens when input pressure reaches a given value.</q><br>
 
<blockquote><q>Unlike the [[Pressure Regulator]], which closes when the input exceeds a given pressure, the back pressure regulator opens when input pressure reaches a given value.</q><br>
 
'''- Stationpedia'''</blockquote>
 
'''- Stationpedia'''</blockquote>
The Back Pressure Regulator will only pass through gases when the pressure on its intake side exceeds the set value. In other words, the standard Regulator defaults '''open''' and closes when the ''output'' is overpressured, while the Back Pressure Regulator defaults '''closed''' and opens when the ''input'' is overpressured.
+
The Back Pressure Regulator is an active powered device for controlled transfer of substances between the two pipe networks. The Back Pressure Regulator will only pass through gases when the pressure on its intake side exceeds the set value. In other words, it prevents the input network from exceeding the set pressure limit by diverting the excess into the output network. When being placed, hologram indicators will display the Input pipe arrow inward, the Output pipe arrow outward, and the power socket on its side. It has a pressure control valve, which defines the target pressure.
  
Like the standard Regulator, the Back Pressure Regulator also acts as a check valve, switched valve, and compressor (i.e., input gas will move even if the output is already a higher pressure).
+
The most common use for a Back Pressure Regulator is as a failsafe mechanism, that can prevent a given pipe network from being overpressurized by a temperate output of other devices, diverting the gas into an arbitrary waste network. Similarly, it can be used to control the pressure within a room, where pressure can fluctuate due to increase in temperature, or has an active gas input to circulate an appropriate atmosphere. However, its low flow rate makes it not suitable for being used as an emergency dump valve in its own right, where a logic-controlled [[Active Vent]] or [[Turbo Volume Pump (Gas)]] would be more appropriate.
  
Its low flow rate makes it not suitable for being used as an emergency dump valve.
+
The maximum pressure that can be set is 60795 kPa - a critical pressure limit for a pipe network before it begin to take damage.
  
 
To calculate the moles per tick, use the following equation:
 
To calculate the moles per tick, use the following equation:
Line 44: Line 43:
 
{{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32 bit integer.}}
 
{{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32 bit integer.}}
 
}}
 
}}
 +
[[Category:Atmospherics]]

Latest revision as of 13:13, 18 May 2025

Back Pressure Regulator
File:StructureBackPressureRegulator.png
Operation
Power Usage 100W
Prefab Hash -1149857558
Prefab Name StructureBackPressureRegulator
Construction
Placed with Kit (Pressure Regulator)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Pressure Regulator)

Description[edit]

Unlike the Pressure Regulator, which closes when the input exceeds a given pressure, the back pressure regulator opens when input pressure reaches a given value.
- Stationpedia

The Back Pressure Regulator is an active powered device for controlled transfer of substances between the two pipe networks. The Back Pressure Regulator will only pass through gases when the pressure on its intake side exceeds the set value. In other words, it prevents the input network from exceeding the set pressure limit by diverting the excess into the output network. When being placed, hologram indicators will display the Input pipe arrow inward, the Output pipe arrow outward, and the power socket on its side. It has a pressure control valve, which defines the target pressure.

The most common use for a Back Pressure Regulator is as a failsafe mechanism, that can prevent a given pipe network from being overpressurized by a temperate output of other devices, diverting the gas into an arbitrary waste network. Similarly, it can be used to control the pressure within a room, where pressure can fluctuate due to increase in temperature, or has an active gas input to circulate an appropriate atmosphere. However, its low flow rate makes it not suitable for being used as an emergency dump valve in its own right, where a logic-controlled Active Vent or Turbo Volume Pump (Gas) would be more appropriate.

The maximum pressure that can be set is 60795 kPa - a critical pressure limit for a pipe network before it begin to take damage.

To calculate the moles per tick, use the following equation: n = (P * V) / (R * T)

Where:

  • P = Min(Input pressure, 101.325)
  • V = 100
  • n = Moles per tick
  • R = Gas constant (8.3144)
  • T = Input temperature

Data Network Properties[edit]

These are all Data Network properties of this device.

Data Parameters[edit]

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).

Click here to see/hide all the data network properties
Parameter Name Data Type Access Value Description
Power Boolean
Read
0 Unpowered Can be read to return if the Back Pressure Regulator is correctly powered or not, set via the power system, return 1 if powered and 0 if not
1 Powered
Error Boolean
Read
0

1 if device is in error state, otherwise 0
1 Error
Lock Boolean
Read Write
0 Unlocked Disable manual operation of the Back Pressure Regulator.
1 Locked
Setting Integer
Read Write
0.0 to 60795.0 A variable setting that can be read or written.
Maximum Float
Read
Maximum setting of the Back Pressure Regulator
Ratio Float
Read
0.0 to 1.0 Context specific value depending on device, 0 to 1 based ratio
On Boolean
Read Write
0 Off The current state of the Back Pressure Regulator.
1 On
RequiredPower Integer
Read
Idle operating power quantity, does not necessarily include extra demand power
PrefabHash Integer
Read
The hash of the structure
ReferenceId Integer
Read
Unique Reference Identifier for this object
NameHash Integer
Read
Provides the hash value for the name of the object as a 32 bit integer.