Difference between revisions of "Pressurant Valve"
From Unofficial Stationeers Wiki
(Created page with "<translate> <!--T:1--> {{Itembox | name = Condensation Valve | image = File:Pressurant Valve.png }} ==Description== <!--T:2--> <!--T:3--> Pumps gas into...") |
Emilgardis (talk | contribs) (omit translate on include) |
||
(3 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | <translate> | + | <noinclude><translate></noinclude> |
<!--T:1--> | <!--T:1--> | ||
− | {{ | + | {{Structurebox |
− | + | | name = Pressurant Valve | |
− | + | | image = [[File:Pressurant Valve.png]] | |
+ | | prefab_hash = 23052817 | ||
+ | | prefab_name = StructurePressurantValve | ||
+ | | power_usage = 100W | ||
+ | | placed_on_grid = Small Grid | ||
+ | | decon_with_tool1 = [[Hand Drill]] | ||
+ | | placed_with_item = [[Kit (Pressure Regulator)]] | ||
+ | | item_rec1 = [[Kit (Pressure Regulator)]] | ||
}} | }} | ||
− | |||
==Description== <!--T:2--> | ==Description== <!--T:2--> | ||
+ | <blockquote><q>Pumps gas into a liquid pipe in order to raise the pressure</q><br> | ||
+ | '''- Stationpedia'''</blockquote> | ||
<!--T:3--> | <!--T:3--> | ||
− | + | ||
− | |||
See also [[Purge Valve]] which does quasi the opposite. | See also [[Purge Valve]] which does quasi the opposite. | ||
− | </translate> | + | {{Data Network Header}} |
+ | {{Data Parameters| | ||
+ | {{Data Parameters/row|Power|Boolean|w=0|Can be read to return if the Pressurant Valve is correctly powered or not, set via the power system, return 1 if powered and 0 if not|multiple=2|0|Unpowered|1|Powered}} | ||
+ | {{Data Parameters/row|Error|Boolean|w=0|1 if device is in error state, otherwise 0|multiple=2|0|<p></p>|1|Error}} | ||
+ | {{Data Parameters/row|Lock|Boolean|Disable manual operation of the Pressurant Valve.|multiple=2|0|Unlocked|1|Locked}} | ||
+ | {{Data Parameters/row|Setting|Integer|A variable setting that can be read or written.|0.0 to 60795.0}} | ||
+ | {{Data Parameters/row|Maximum|Float|w=0|Maximum setting of the Pressurant Valve}} | ||
+ | {{Data Parameters/row|Ratio|Float|w=0|Context specific value depending on device, 0 to 1 based ratio|0.0 to 1.0}} | ||
+ | {{Data Parameters/row|On|Boolean|The current state of the Pressurant Valve.|multiple=2|0|Off|1|On}} | ||
+ | {{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}} | ||
+ | {{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}} | ||
+ | {{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}} | ||
+ | {{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32 bit integer.}} | ||
+ | }} | ||
+ | |||
+ | <noinclude></translate></noinclude> | ||
+ | |||
[[Category:Atmospherics]] | [[Category:Atmospherics]] |
Latest revision as of 05:46, 10 July 2024
Operation | |
---|---|
Power Usage | 100W |
Prefab Hash | 23052817 |
Prefab Name | StructurePressurantValve |
Construction | |
Placed with | Kit (Pressure Regulator) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Pressure Regulator) |
Description[edit]
Pumps gas into a liquid pipe in order to raise the pressure
- Stationpedia
See also Purge Valve which does quasi the opposite.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Click here to see/hide all the data network properties
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Pressurant Valve is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
1 | Error | |||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Pressurant Valve. | |
1 | Locked | |||||
Setting | Integer | Read Write
|
0.0 to 60795.0 | |||
Maximum | Float | Read
|
||||
Ratio | Float | Read
|
0.0 to 1.0 | |||
On | Boolean | Read Write
|
0 | Off | The current state of the Pressurant Valve. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|