Difference between revisions of "Purge Valve"
From Unofficial Stationeers Wiki
Emilgardis (talk | contribs) (add structurebox and data params) |
Emilgardis (talk | contribs) (omit translate on include) |
||
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
− | <translate> | + | <noinclude><translate></noinclude> |
<!--T:1--> | <!--T:1--> | ||
{{Structurebox | {{Structurebox | ||
| name = Purge Valve | | name = Purge Valve | ||
− | | image = [[File: | + | | image = [[File:Purge Valve.png]] |
| prefab_hash = -737232128 | | prefab_hash = -737232128 | ||
| prefab_name = StructurePurgeValve | | prefab_name = StructurePurgeValve | ||
Line 36: | Line 36: | ||
}} | }} | ||
− | </translate> | + | <noinclude></translate></noinclude> |
[[Category:Atmospherics]] | [[Category:Atmospherics]] |
Latest revision as of 05:46, 10 July 2024
Operation | |
---|---|
Power Usage | 100W |
Prefab Hash | -737232128 |
Prefab Name | StructurePurgeValve |
Construction | |
Placed with | Kit (Pressure Regulator) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Pressure Regulator) |
Description[edit]
Allows for removal of pressurant gas and evaporated liquids from a liquid pipe. Similar in function to a Back Pressure Regulator the Purge Valve moves gas from the input liquid pipe to the output gas pipe aiming to keep the pressure of the input at the target setting.
- Stationpedia
See also Pressurant Valve which does quasi the opposite.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Click here to see/hide all the data network properties
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Purge Valve is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
1 | Error | |||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Purge Valve. | |
1 | Locked | |||||
Setting | Integer | Read Write
|
0.0 to 60795.0 | |||
Maximum | Float | Read
|
||||
Ratio | Float | Read
|
0.0 to 1.0 | |||
On | Boolean | Read Write
|
0 | Off | The current state of the Purge Valve. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|