Difference between revisions of "Purge Valve"
From Unofficial Stationeers Wiki
Emilgardis (talk | contribs) (add structurebox and data params) |
|||
Line 1: | Line 1: | ||
<translate> | <translate> | ||
<!--T:1--> | <!--T:1--> | ||
− | {{ | + | {{Structurebox |
− | + | | name = Purge Valve | |
− | + | | image = [[File:StructurePurgeValve.png]] | |
+ | | prefab_hash = -737232128 | ||
+ | | prefab_name = StructurePurgeValve | ||
+ | | power_usage = 100W | ||
+ | | placed_on_grid = Small Grid | ||
+ | | decon_with_tool1 = [[Hand Drill]] | ||
+ | | placed_with_item = [[Kit (Pressure Regulator)]] | ||
+ | | item_rec1 = [[Kit (Pressure Regulator)]] | ||
}} | }} | ||
− | |||
==Description== <!--T:2--> | ==Description== <!--T:2--> | ||
<!--T:3--> | <!--T:3--> | ||
− | Allows for | + | <blockquote><q>Allows for removal of pressurant gas and evaporated liquids from a liquid pipe. Similar in function to a [[Back Pressure Regulator]] the [[Purge Valve]] moves gas from the input liquid pipe to the output gas pipe aiming to keep the pressure of the input at the target setting.</q><br> |
− | < | + | '''- Stationpedia'''</blockquote> |
+ | |||
See also [[Pressurant Valve]] which does quasi the opposite. | See also [[Pressurant Valve]] which does quasi the opposite. | ||
+ | <!--T:4--> | ||
+ | {{Data Network Header}} | ||
+ | {{Data Parameters| | ||
+ | {{Data Parameters/row|Power|Boolean|w=0|Can be read to return if the Purge Valve is correctly powered or not, set via the power system, return 1 if powered and 0 if not|multiple=2|0|Unpowered|1|Powered}} | ||
+ | {{Data Parameters/row|Error|Boolean|w=0|1 if device is in error state, otherwise 0|multiple=2|0|<p></p>|1|Error}} | ||
+ | {{Data Parameters/row|Lock|Boolean|Disable manual operation of the Purge Valve.|multiple=2|0|Unlocked|1|Locked}} | ||
+ | {{Data Parameters/row|Setting|Integer|A variable setting that can be read or written.|0.0 to 60795.0}} | ||
+ | {{Data Parameters/row|Maximum|Float|w=0|Maximum setting of the Purge Valve}} | ||
+ | {{Data Parameters/row|Ratio|Float|w=0|Context specific value depending on device, 0 to 1 based ratio|0.0 to 1.0}} | ||
+ | {{Data Parameters/row|On|Boolean|The current state of the Purge Valve.|multiple=2|0|Off|1|On}} | ||
+ | {{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}} | ||
+ | {{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}} | ||
+ | {{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}} | ||
+ | {{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32 bit integer.}} | ||
+ | }} | ||
</translate> | </translate> | ||
[[Category:Atmospherics]] | [[Category:Atmospherics]] |
Revision as of 05:30, 10 July 2024
File:StructurePurgeValve.png | |
Operation | |
---|---|
Power Usage | 100W |
Prefab Hash | -737232128 |
Prefab Name | StructurePurgeValve |
Construction | |
Placed with | Kit (Pressure Regulator) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Pressure Regulator) |
Description
Allows for removal of pressurant gas and evaporated liquids from a liquid pipe. Similar in function to a Back Pressure Regulator the Purge Valve moves gas from the input liquid pipe to the output gas pipe aiming to keep the pressure of the input at the target setting.
- Stationpedia
See also Pressurant Valve which does quasi the opposite.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Click here to see/hide all the data network properties
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Purge Valve is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
1 | Error | |||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Purge Valve. | |
1 | Locked | |||||
Setting | Integer | Read Write
|
0.0 to 60795.0 | |||
Maximum | Float | Read
|
||||
Ratio | Float | Read
|
0.0 to 1.0 | |||
On | Boolean | Read Write
|
0 | Off | The current state of the Purge Valve. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|