Actions

Difference between revisions of "Pressurant Valve"

From Unofficial Stationeers Wiki

Line 19: Line 19:
 
{{Data Parameters/row|Error|Boolean|w=0|1 if device is in error state, otherwise 0|multiple=2|0|<p></p>|1|Error}}
 
{{Data Parameters/row|Error|Boolean|w=0|1 if device is in error state, otherwise 0|multiple=2|0|<p></p>|1|Error}}
 
{{Data Parameters/row|Lock|Boolean|Disable manual operation of the Active Vent.|multiple=2|0|Unlocked|1|Locked}}
 
{{Data Parameters/row|Lock|Boolean|Disable manual operation of the Active Vent.|multiple=2|0|Unlocked|1|Locked}}
{{Data Parameters/row|Setting|Integer|A variable setting that can be read or written.}}
+
{{Data Parameters/row|Setting|Integer|w=0|A variable setting that can be read or written.|0.0 to 60795.0}}
 
{{Data Parameters/row|Maximum|Integer|w=0|Maximum setting of the device}}
 
{{Data Parameters/row|Maximum|Integer|w=0|Maximum setting of the device}}
 
{{Data Parameters/row|Ratio|Float|w=0|Context specific value depending on device, 0 to 1 based ratio|0.0 to 1.0}}
 
{{Data Parameters/row|Ratio|Float|w=0|Context specific value depending on device, 0 to 1 based ratio|0.0 to 1.0}}

Revision as of 11:57, 9 July 2024

Pressurant Valve
Pressurant Valve.png


Description

Pumps gas into a liquid pipe in order to raise the pressure.

See also Purge Valve which does quasi the opposite.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).

Click here to see/hide all the data network properties
Parameter Name Data Type Access Value Description
Power Boolean
Read
0 Off Can be read to return if the device is correctly powered or not, set via the power system, return 1 if powered and 0 if not
1 On
Error Boolean
Read
0

1 if device is in error state, otherwise 0
1 Error
Lock Boolean
Read Write
0 Unlocked Disable manual operation of the Active Vent.
1 Locked
Setting Integer
Read
0.0 to 60795.0 A variable setting that can be read or written.
Maximum Integer
Read
Maximum setting of the device
Ratio Float
Read
0.0 to 1.0 Context specific value depending on device, 0 to 1 based ratio
On Boolean
Read Write
0 Off The current state of the Active Vent.
1 On
RequiredPower Integer
Read
Idle operating power quantity, does not necessarily include extra demand power
PrefabHash Integer
Read
The hash of the structure
ReferenceId Integer
Read
Unique Reference Identifier for this object
NameHash Integer
Read
Provides the hash value for the name of the object as a 32 bit integer.