Difference between revisions of "Control Chair"
From Unofficial Stationeers Wiki
F1r3w4rr10r (talk | contribs) m (Add to Data Network category) |
m (Added picture) |
||
(4 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
[[Category:Data Network]] | [[Category:Data Network]] | ||
− | {{ | + | {{Structurebox |
− | | name | + | | name = Control Chair |
− | | | + | | image = [[File:ControlChair.png]] |
− | | | + | | power_usage = 250W |
− | | | + | | placed_with_item = [[Kit (Furniture)]] |
+ | | placed_on_grid = Small Grid | ||
+ | | decon_with_tool1 = [[Hand Drill]] | ||
+ | | item_rec1 = [[Kit (Furniture)]] | ||
}} | }} | ||
The '''Control Chair''' is a piece of furniture, which is constructed with the [[Kit (Furniture)]]. | The '''Control Chair''' is a piece of furniture, which is constructed with the [[Kit (Furniture)]]. | ||
− | + | {{Data Network Header}} | |
− | |||
− | + | {{Data Parameters}} | |
− | |||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 24: | Line 25: | ||
|} | |} | ||
− | + | {{Data Outputs}} | |
− | |||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- |
Latest revision as of 20:06, 4 January 2021
Operation | |
---|---|
Power Usage | 250W |
Construction | |
Placed with | Kit (Furniture) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Furniture) |
The Control Chair is a piece of furniture, which is constructed with the Kit (Furniture).
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Mode | Integer | (Unknown) Accepts a range from 0 to 2. Affects the Mode output. |
Setting | Float | (Unknown) Accepts a range from 0.0 to 100.0. Affects the Setting output. |
On | Boolean | (Unknown) Supposedly turns the Control Chair on, when set to 1. Turns it off, when set to 0. Affects the On output. |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Control Chair is turned on and receives power. (0 for no, 1 for yes) |
Mode | Integer | (Unknown) Returns a range from 0 to 2. Is affected by the Mode parameter. |
Error | Boolean | Returns whether the Control Chair is flashing an error. |
Setting | Float | (Unknown) Returns a range from 0.0 to 100.0. Is affected by the Setting parameter. |
Maximum | Integer | (Unknown) Returns 100. |
Ratio | Float | Returns a range from 0.0 to 1.0. Returns the ratio of the set Setting to the Maximum. |
On | Boolean | Returns whether the Control Chair is turned on. (0 for no, 1 for yes) |
RequiredPower | Returns the power, currently needed by the Control Chair, in watts. |