Composite Door
From Unofficial Stationeers Wiki
(Redirected from Kit (Door) Composite Door)
File:StructureCompositeDoor.png | |
Operation | |
---|---|
Power Usage | 10W |
Prefab Hash | -793837322 |
Prefab Name | StructureCompositeDoor |
Construction | |
Placed with | Kit (Door) |
Placed on | Small Grid |
Stage 1 | |
Next Stage Construction | |
Constructed with tool | Welding Torch |
Constructed with item | 1 x Plastic Sheets |
Deconstruction | |
Deconstructed with | Wrench |
Item received | Kit (Door) |
Stage 2 | |
Next Stage Construction | |
Constructed with tool | Crowbar |
Constructed with item | 1 x Glass Sheets |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | 1 x Plastic Sheets |
Stage 3 | |
Deconstruction | |
Deconstructed with | Angle Grinder |
Item received | 1 x Glass Sheets |
Contents
Purpose[edit]
A Composite Door is one type of door created using the Kit (Door).
Characteristics[edit]
- The Door allows separation between two different rooms.
- It consumes 10W of Power per Tick.
- It has a separate Power Port and Data Port.
Tips[edit]
- A Crowbar can be used to force the door open, as long as it is not Locked.
User Interface[edit]
An <ITEM> has no user interface. An <ITEM> provides the following user interface:
Name | Type | Function |
---|---|---|
<Name> | <Type> | <Function> |
Settings[edit]
An <ITEM> has no settings. An <ITEM> will have the following settings:
Name | Description |
---|---|
<Name> | <Description> |
Construction[edit]
- 1x Plastic Sheets using a Welding Torch.
- 1x Glass Sheets using a Crowbar.
Deconstruction[edit]
The following tools must be used in order to deconstruct the Door:
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Click here to see/hide all the data network properties
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Composite Door is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Open | Integer | Read Write
|
0 | Closed | 1 if device is open, otherwise 0 | |
1 | Open | |||||
Mode | Integer | Read Write
|
0 | Operate | The mode of the Composite Door. In logic mode you must continuously copy Setting to Open to have the effect of Operate mode. | |
1 | Logic | |||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Composite Door. | |
1 | Locked | |||||
Setting | Integer | Read Write
|
||||
On | Boolean | Read Write
|
0 | Off | The current state of the Composite Door. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
Idle | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|
See Also[edit]