Actions

Template

Difference between revisions of "Data Parameters"

From Unofficial Stationeers Wiki

(added ic10)
(Data Parameters)
Line 1: Line 1:
 
=== Data Parameters ===
 
=== Data Parameters ===
{{#if: {{{1|}}}|This device does not have any logic parameters and can not be selected with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]].|These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]], [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]], or [[Integrated Circuit (IC10)]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.}}
+
{{#if: {{{1|}}}|This device does not have any logic parameters and can not be selected with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]].|These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]], [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]], or [[Integrated Circuit (IC10)]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
 +
Edit: In Logic Mode the setting parameter is set to 1 when the door is activated by an user. It has to be reset to 0 by your logic afterwars to function again. The information below, that the settings parameter has no function is misleading. And the device has actually an interface - the door keypad. Unfortunately I dont know how to alter the parameter table itself  sorry.}}
 
<noinclude>
 
<noinclude>
 
{{Documentation}}
 
{{Documentation}}
 
<!-- Categories go on the /doc subpage, and interwikis go on Wikidata. -->
 
<!-- Categories go on the /doc subpage, and interwikis go on Wikidata. -->
 
</noinclude>
 
</noinclude>

Revision as of 09:54, 3 March 2024

Data Parameters

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them. Edit: In Logic Mode the setting parameter is set to 1 when the door is activated by an user. It has to be reset to 0 by your logic afterwars to function again. The information below, that the settings parameter has no function is misleading. And the device has actually an interface - the door keypad. Unfortunately I dont know how to alter the parameter table itself sorry.

Template documentation[view] [edit] [history] [purge]

Data Parameters template

This template is meant to be used for Structures, that support connections to the Data Network. It provides a heading for Data parameters. If anything is passed to the first positional parameter of the template, it will display a text that indicates, that the structure does not have any parameters.