Actions

Talk

Editing Furnace temperature and pressure math

Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.

The edit can be undone. Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision Your text
Line 98: Line 98:
 
#The obtained value was 4.99999 J per ignite.
 
#The obtained value was 4.99999 J per ignite.
 
#The experiment was repeated with a larger amount of N2. The obtained value was 5.0126 J per ignite.
 
#The experiment was repeated with a larger amount of N2. The obtained value was 5.0126 J per ignite.
 
===Measuring R in PV=nRT just to see what happens===
 
#A MIPS program was prepared to calculate and display R=(PV)/(nT)
 
*50.00kPa gave R = 8.31439978
 
*38.89kPa gave R = 8.31440004
 
*15.12kPa gave R = 8.31439978
 
*10.64kPa gave R = 8.31440002
 
*10.44kPa gave R = 8.31439940
 
The value fluctuates in the 8th digit. This is espcially easy to see by inserting/releasing gas slowly and watching the value change. There is a precision error here, maybe a result of a rounding error in the game. Since it appears random, it can't explain the error in the released energy above, since that one has a trend.
 

Please note that all contributions to Unofficial Stationeers Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see Unofficial Stationeers Wiki:Copyrights for details). Do not submit copyrighted work without permission!

To edit this page, please answer the question that appears below (more info):

Cancel | Editing help (opens in new window)