{{Structurebox
 +
| name            = Filtration
 +
| power_usage      = 5w
 +
| placed_with_item = [[Kit (Atmospherics)]]
 +
| placed_on_grid  = Small Grid
 +
| decon_with_tool1 = [[Hand Drill]]
 +
| item_rec1        = [[Kit (Atmospherics)]]
 +
}}
 +
<!--T:1-->
 +
==Purpose==
 +
A Filtration unit is a powered Atmospheric processor used to filter specific gases from a mixture. [[Guide (Filtration)]] provides additional information regarding the function, construction, and operation of a Filtration unit.
 +
 
 +
<!--T:2-->
 +
==Characteristics==
 +
* It has a manual power switch.
 +
* It consumes 10W of [[Power]] per [[Tick]] when idle and 44W when active.
 +
* It has a separate [[Power Port]] and [[Data Port]].
 +
* It has a pipe port (labelled "Input") for the gas mixture from which the designated gas(es) '''will be''' filtered.
 +
* It has a pipe port (labelled "Filtered") for the designated gas(es) that '''have been''' filtered.
 +
* It has a pipe port (labelled "Unfiltered") for any remaining unfiltered gases.
 +
* It can filter up to 2 different gases at once by inserting two different filters.
 +
Note: When using an I/O slot reader chip, the filter slots are labeled as slot 1, slot 2 and slot 3(IC), with 1 being the slot closer to the inlet.
 +
When using an IC chip, the slots are labeled as slot 0, slot1 and slot 2(IC).
 +
 
 +
==User Interface==
 +
A Filtration unit provides the following user interface:
 +
{| class="wikitable"
 +
|-
 +
! Name || Type !! Function
 +
|-
 +
| [[Filters|Filter]] (Right) || Slot 0 || Port for a gas filter. If gas of the same type is present in the incoming mixture, it will be redirected out the "Filtered" pipe port.
 +
|-
 +
| Filter (Left) || Slot 1 || Another Port for a gas filter that functions the same as its twin slot. May contain the same or a different filter.
 +
|-
 +
| v || Slot 2 || IC10 placed in filtration unit (has 2 Input/Outputs)
 +
|-
 +
| On || Switch || Switches Filtration unit between turned on or turned off. (On=1/Off=0)
 +
|-
 +
|}
 +
 
 +
{{Data Network Header}}
 +
 
 +
{{Data Parameters}}
 +
<!--T:4-->
 +
{| class="wikitable"
 +
|-
 +
! Parameter Name !! Data Type !! Description
 +
|-
 +
| On || Boolean || Powers on the Filtration unit on when set to 1. Powers off when set to 0.
 +
|-
 +
| Open || Boolean  ||
 +
|-
 +
| Setting || Integer ||
 +
|-
 +
| Lock || Boolean ||
 +
|-
 +
| Mode || Boolean  || 0: idle, 1: Active
 +
|}
 +
 
 +
{{Data Outputs}}
 +
<!--T:5-->
 +
{| class="wikitable"
 +
|-
 +
! Output Name !! Data Type !! Description
 +
|-
 +
| Power || Boolean || Returns whether the Filtration unit is turned on and receives power. (0 for no, 1 for yes)
 +
|-
 +
| Error || Boolean || Returns whether the Filtration unit is flashing an error. (0 for no, 1 for yes)
 +
|-
 +
| Lock || Boolean || Returns whether the Filtration unit is locked. (0 for no, 1 for yes)
 +
|-
 +
| On || Boolean || Returns whether the Filtration unit is turned on. (0 for no, 1 for yes)
 +
|-
 +
| RequiredPower || Integer || Returns the current amount of power in Watts required by the Filtration unit.
 +
|-
 +
| Quantity || Integer || Returns the current amount of Filter remaining. Slot 0 (Right), slot 1 (Left).
 +
|}
 +
 
 +
<!--T:6-->
 +
==Slot Outputs==
 +
Slot0= Filter Left , Slot1= Filter Right , Slot2= Programmable Chip
 +
 
 +
{| class="wikitable"
 +
|-
 +
! Output Name !! Data Type !! Description
 +
|-
 +
| OccupantHash || Integer || Filter cartridge Hash-code (Identifier)
 +
|-
 +
| Occupied || Boolean || 0/1 filter slot empty/occupied
 +
|-
 +
| PrefabHash || Integer ||
 +
|-
 +
| Quantity || Integer || Remaining life of filter cartridge.
 +
|-
 +
| Class || Integer ||
 +
|-
 +
| Dammage || Integer ||
 +
|-
 +
| MaxQuantity || Integer || Max. life of filter cartridge
 +
|}
 +
 
 +
<!--T:7-->
 +
==See Also==
 +
* [[Guide (Filtration)]]
 +
 
 +
* [[Kit (Atmospherics)]]
 +
* [[Kit (Portable Scrubber) Portable Scrubber|Portable Scrubber]]
 +
</translate>

Please note that all contributions to Unofficial Stationeers Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see Unofficial Stationeers Wiki:Copyrights for details). Do not submit copyrighted work without permission!

To edit this page, please answer the question that appears below (more info):

Cancel | Editing help (opens in new window)