Actions

Editing Guide (Airlock) Atmosphere to Atmosphere

Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.

The edit can be undone. Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision Your text
Line 31: Line 31:
 
# Place two [[Portal]]s one [[Large Grid]] apart with the power and data ports facing into the airlock's interior.
 
# Place two [[Portal]]s one [[Large Grid]] apart with the power and data ports facing into the airlock's interior.
 
# Using the [[Labeller]], rename each portal as "Interior-Door" and "Exterior-Door" appropriately.
 
# Using the [[Labeller]], rename each portal as "Interior-Door" and "Exterior-Door" appropriately.
# Ensure the "Exterior-Door" is OPEN, and the "Interior-Door" is CLOSED.
+
# Enclose the six remaining sides of the airlock chamber with airtight [[Frames]], [[Walls]], or [[Windows]].
# Enclose the four remaining sides of the airlock chamber with airtight [[Frames]], [[Walls]], or [[Windows]].
 
 
# Place [[Console]], [[Active Vent]]s, [[Gas Sensor]], and optional [[Flashing Light]] and [[Power Controller]] somewhere within the airlock's interior.
 
# Place [[Console]], [[Active Vent]]s, [[Gas Sensor]], and optional [[Flashing Light]] and [[Power Controller]] somewhere within the airlock's interior.
 
# Ensure all placed devices are attached to the same [[Wire Network]] including the portals' power and data ports.
 
# Ensure all placed devices are attached to the same [[Wire Network]] including the portals' power and data ports.
Line 38: Line 37:
 
# Using the Labeller, rename each Active Vent as "Interior Vent" and "Exterior Vent" appropriately.
 
# Using the Labeller, rename each Active Vent as "Interior Vent" and "Exterior Vent" appropriately.
 
# Attach a [[Pipe Network]] to each Active Vent large enough to hold the volume of the airlock or pass it through to a [[Passive Vent]] placed in the "interior" or "exterior" environment.  
 
# Attach a [[Pipe Network]] to each Active Vent large enough to hold the volume of the airlock or pass it through to a [[Passive Vent]] placed in the "interior" or "exterior" environment.  
# Ensure "interior" and "exterior" pipe networks are not connected together or to any other pipe networks.[[File:Guide adv airlock bare.jpg|thumb|advanced airlock with 2 walls removed for better visibility]]
+
# Ensure "interior" and "exterior" pipe networks are not connected together or to any other pipe networks.
 
# Insert [[Circuitboard (Advanced Airlock)]] into the console, then place the [[Glass Sheet]] onto the console.
 
# Insert [[Circuitboard (Advanced Airlock)]] into the console, then place the [[Glass Sheet]] onto the console.
# Insert [[Data Disk]] into the side slot of Console then power on the Console.[[File:Guide adv airlock config0.png|thumb|slot to insert data disk]]
+
# Insert [[Data Disk]] into the side slot of Console then power on the Console.
# '''The following steps may be done with the game paused.'''
 
 
# Use the console's up and down arrows to scroll through the list of devices. Click to select. Click again to deselect if incorrect
 
# Use the console's up and down arrows to scroll through the list of devices. Click to select. Click again to deselect if incorrect
# Find and click "Exterior-Door" followed by all caps and green "EXTERIOR". NOTE: SELECT THIS FIRST![[File:Guide adv airlock config1.png|thumb|make sure to click the exterior door and vent first]]
+
# Find and click "Exterior-Door" followed by all caps and green "EXTERIOR". NOTE: SELECT THIS FIRST!
 
# Ensure the Exterior-Door's lock-indicator has turned from green to red.
 
# Ensure the Exterior-Door's lock-indicator has turned from green to red.
 
# Find and click "Exterior-Vent" followed by all caps and green "EXTERIOR". NOTE: SELECT THIS SECOND!
 
# Find and click "Exterior-Vent" followed by all caps and green "EXTERIOR". NOTE: SELECT THIS SECOND!
Line 52: Line 50:
 
# Find and click "Flashing Light" followed by all caps and green "LIGHT". (optional)
 
# Find and click "Flashing Light" followed by all caps and green "LIGHT". (optional)
 
# Toward the top left of the Console find and click "External ###Pa". Set to match the exterior-environment's typical pressure. (optional)
 
# Toward the top left of the Console find and click "External ###Pa". Set to match the exterior-environment's typical pressure. (optional)
# Toward the top right of the Console find and click "Internal ###Pa". Set to match the interior-environment's typical pressure. (optional)[[File:Guide adv airlock config3.png|thumb|set pressures appropriate to each side]]
+
# Toward the top right of the Console find and click "Internal ###Pa". Set to match the interior-environment's typical pressure. (optional)
 
# Remove Data Disk from the side slot of Console.
 
# Remove Data Disk from the side slot of Console.
 
<br>If there is an error the console screen will say so and the power light will flash yellow.
 
<br>If there is an error the console screen will say so and the power light will flash yellow.
Line 78: Line 76:
  
 
A depressurization phase will stall if a complete vacuum cannot be achieved within the [[Large Grid Atmosphere|Large Grid Volume]]s in which all selected [[Gas Sensor]]s reside. Such stalled depressurization can be skipped by clicking the yellow "Cancel Depressurize" button on a console, but atmospheric mixing may occur. In larger airlocks, ensure there is one Gas Sensor per Large Grid to prevent premature repressurization and the resulting mixture of interior and exterior atmospheres.
 
A depressurization phase will stall if a complete vacuum cannot be achieved within the [[Large Grid Atmosphere|Large Grid Volume]]s in which all selected [[Gas Sensor]]s reside. Such stalled depressurization can be skipped by clicking the yellow "Cancel Depressurize" button on a console, but atmospheric mixing may occur. In larger airlocks, ensure there is one Gas Sensor per Large Grid to prevent premature repressurization and the resulting mixture of interior and exterior atmospheres.
 
The setup of slave consoles <em>may</em> still be bugged in such a way that after initial setup the slave console will show the config of an airlock, but be grayed out and not accept any input. It has been noted in several community posts that saving the game, quitting out of the game, and then reloading the save will allow the slave consoles to work after the reload.
 
  
 
==See Also==
 
==See Also==

Please note that all contributions to Unofficial Stationeers Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see Unofficial Stationeers Wiki:Copyrights for details). Do not submit copyrighted work without permission!

To edit this page, please answer the question that appears below (more info):

Cancel | Editing help (opens in new window)