Actions

Editing Guide (Airlock) Atmosphere to Atmosphere

Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.

The edit can be undone. Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision Your text
Line 3: Line 3:
 
<translate>
 
<translate>
 
==Description==
 
==Description==
An Atmosphere to Atmosphere Airlock is a [[Room]] that can evacuate its internal volume and refill it with either of the two differing [[Atmosphere]]s it connects. It has two airtight [[Portal]]s which do not open simultaneously. An Atmosphere to Atmosphere Airlock allows passage between two environments without the exchange of [[Gas]]es or [[Pressure]].
+
An Atmosphere to Atmosphere Airlock is a [[Room|chamber]] that can evacuate its internal volume and refill it with either of the two differing [[Atmosphere|atmospheres]] it connects. It has two or more airtight portals which all do not open simultaneously. Thus, an Atmosphere to Atmosphere Airlock allows passage between the two environments without the exchange of [[Gas|gases]] or [[Pressure|pressures]] between the separate atmospheres.
  
An Atmosphere to Atmosphere Airlock can be controlled automatically using a [[Circuitboard (Advanced Airlock)]] installed within a [[Console]] which will refer to each of the two separated environments as either "interior" or "exterior".
+
An Atmosphere to Atmosphere Airlock can be controlled automatically by an [[Circuitboard (Advanced Airlock)]] installed within a [[Console]].
  
When activated with the interior-portal open, the system will automatically close the interior-portal and will activate the interior-[[Active Vent|Active-Vent]] to try to evacuate the interior-atmosphere from the airlock chamber. Once a total vacuum is achieved within all of the [[Large Grid Atmosphere|Large Grid Volume]]s in which selected [[Gas Sensor]]s reside, the airlock will activate the exterior-Active-Vent to try to pressurize the chamber with exterior-atmosphere. Only after the internal pressure within all of the Large Grid Volumes in which selected Gas Sensors reside equals or exceeds the "External ###Pa" specified in the [[Circuitboard (Advanced Airlock)#Settings|Circuitboard's settings]] will the exterior-portal automatically open.  
+
The Circuitboard (Advanced Airlock)'s settings will refer to the two adjoining environments as either "interior" or "exterior" and, when powered, all associated doors and vents are locked, preventing their manual use even when power is subsequently denied.
  
When activated with the exterior-portal open, a similar process to the above is executed, swapping interior for exterior, exterior for interior, and the final airlock pressure governed by the "Internal ###Pa" setting instead.
+
If the "interior" door is open, then when activated the Circuitboard (Advanced Airlock) will automatically close the interior-door and evacuate the interior-atmosphere from the airlock chamber out into/through the pipe-network attached to the interior-vent. Once a total vacuum is achieved, the Circuitboard (Advanced Airlock) will replace the airlock's vacuum with the exterior-atmosphere from/through the pipe-network attached to the exterior-vent and then open the exterior-door. The reverse process is executed when the system is activated with the "exterior" door open.
  
 
==Materials==
 
==Materials==
Material requirements for a minimnum Atmosphere to Atmosphere Airlock are:
+
Material requirements for an minimnum Atmosphere to Atmosphere Airlock are:
* 2 x [[Portal]]: variants of either [[Kit (Airlock)]], [[Kit (Blast Door)]], [[Kit (Door)]], or [[Kit (Docking Port)]]
+
* 2 x portals: varients of either [[Kit (Airlock)]], [[Kit (Blast Door)]], [[Kit (Door)]], or [[Kit (Docking Port)]]
* 1 x [[Kit (Consoles) Console|Kit (Consoles) Console]]  
+
* 1 x [[Kit (Consoles) Console|Kit (Consoles) Console]]  
* 1 x [[Circuitboard (Advanced Airlock)]]
+
* 1 x [[Circuitboard (Advanced Airlock)]]
* 1 x [[Glass Sheets]]
+
* 1 x [[Glass Sheets]]
* 1 x [[Data Disk]]
+
* 1 x [[Data Disk]]
* 1 x [[Kit (Sensors) Gas Sensor]]
+
* 1 x [[Kit (Sensors) Gas Sensor]]
* 2 x [[Kit (Active Vent)]]
+
* 2 x [[Kit (Active Vent)]]
* 2 x [[Kit (Passive Vent)]] (optional)
+
* 2 x [[Kit (Passive Vent)]] (optional)
* 1 x [[Kit (Flashing Light)]] (optional)
+
* 1 x [[Kit (Flashing Light)]] (optional)
* 1 x [[Kit (Power Controller)]] (optional)
+
* 1 x [[Kit (Power Controller)]] (optional)
* 4 x [[Kit (Pipe)]]
+
* 4 x [[Kit (Pipe)]]
* # x [[Cable Coil]]
+
* ?? x [[Cable Coil]]
  
 
==Construction==
 
==Construction==
 
A minimum Atmosphere to Atmosphere Airlock can be constructed using the following instructions:
 
A minimum Atmosphere to Atmosphere Airlock can be constructed using the following instructions:
  
# Place two [[Portal]]s one [[Large Grid]] apart with the power and data ports facing into the airlock's interior.
+
# Place both doors one large grid apart with the power and data ports facing into the airlock chamber's interior.
# Using the [[Labeller]], rename each portal as "Interior-Door" and "Exterior-Door" appropriately.
+
# Using the [[Labeller]], rename each door as "Interior-Door" and "Exterior-Door" appropriately.
# Ensure the "Exterior-Door" is OPEN, and the "Interior-Door" is CLOSED.
+
# Enclose the six remaining sides of the airlock chamber with airtight frames, walls, or windows.
# Enclose the four remaining sides of the airlock chamber with airtight [[Frames]], [[Walls]], or [[Windows]].
+
# Place Console, Active Vents, Gas Sensor, optional Flashing Light, and optional Power Controller such that they all can be wired together on the same network including the doors' power and data ports.
# Place [[Console]], [[Active Vent]]s, [[Gas Sensor]], and optional [[Flashing Light]] and [[Power Controller]] somewhere within the airlock's interior.
+
# Attach enough pipes to each Active Vent to hold the volume of the airlock chamber or pass it through to a Passive Vent placed in the "interior" or "exterior" environment.
# Ensure all placed devices are attached to the same [[Wire Network]] including the portals' power and data ports.
+
# Using the [[Labeller]], rename each Active Vents as "Interior Vent" and "Exterior Vent" appropriately.
# Ensure the airlock's wire network is connected to an active [[Power Supply]] and all devices can receive power.
+
# Ensure "interior" and "exterior" pipe-networks are not connected.
# Using the Labeller, rename each Active Vent as "Interior Vent" and "Exterior Vent" appropriately.
+
# Ensure the airlock's wire-network is connected to an active power supply and all devices can receive power.
# Attach a [[Pipe Network]] to each Active Vent large enough to hold the volume of the airlock or pass it through to a [[Passive Vent]] placed in the "interior" or "exterior" environment.  
+
# Insert Circuitboard (Advanced Airlock) into the console, then place the glass sheet onto the console.
# Ensure "interior" and "exterior" pipe networks are not connected together or to any other pipe networks.[[File:Guide adv airlock bare.jpg|thumb|advanced airlock with 2 walls removed for better visibility]]
+
# Insert Data Disk into the side slot of Console and power on the Console.
# Insert [[Circuitboard (Advanced Airlock)]] into the console, then place the [[Glass Sheet]] onto the console.
+
# On the Console, scroll through the list of devices. Click to select. Click again to deselect if incorrect
# Insert [[Data Disk]] into the side slot of Console then power on the Console.[[File:Guide adv airlock config0.png|thumb|slot to insert data disk]]
+
# Find and click "Exterior-Door" followed by all caps and green "EXTERIOR". NOTE: SELECT THIS FIRST!
# '''The following steps may be done with the game paused.'''
 
# Use the console's up and down arrows to scroll through the list of devices. Click to select. Click again to deselect if incorrect
 
# Find and click "Exterior-Door" followed by all caps and green "EXTERIOR". NOTE: SELECT THIS FIRST![[File:Guide adv airlock config1.png|thumb|make sure to click the exterior door and vent first]]
 
 
# Ensure the Exterior-Door's lock-indicator has turned from green to red.
 
# Ensure the Exterior-Door's lock-indicator has turned from green to red.
 
# Find and click "Exterior-Vent" followed by all caps and green "EXTERIOR". NOTE: SELECT THIS SECOND!
 
# Find and click "Exterior-Vent" followed by all caps and green "EXTERIOR". NOTE: SELECT THIS SECOND!
Line 52: Line 49:
 
# Find and click "Flashing Light" followed by all caps and green "LIGHT". (optional)
 
# Find and click "Flashing Light" followed by all caps and green "LIGHT". (optional)
 
# Toward the top left of the Console find and click "External ###Pa". Set to match the exterior-environment's typical pressure. (optional)
 
# Toward the top left of the Console find and click "External ###Pa". Set to match the exterior-environment's typical pressure. (optional)
# Toward the top right of the Console find and click "Internal ###Pa". Set to match the interior-environment's typical pressure. (optional)[[File:Guide adv airlock config3.png|thumb|set pressures appropriate to each side]]
+
# Toward the top right of the Console find and click "Internal ###Pa". Set to match the interior-environment's typical pressure. (optional)
 
# Remove Data Disk from the side slot of Console.
 
# Remove Data Disk from the side slot of Console.
<br>If there is an error the console screen will say so and the power light will flash yellow.
+
 +
If there is an error the console screen will say so and the power light will flash yellow.
  
 
==Console Slaves==
 
==Console Slaves==
Additional consoles are useful when airlocks become large or remote control is desired. Multiple [[Circuitboard (Advanced Airlock)#Console Slave|Console Slave]]s can be attached using the following instructions:
+
When additional airlock controls are desired, they can be attached using the following instructions:
  
# Using the [[Labeller]], rename the original [[Console]] as "Master Console".
+
# Using the [[Labeller]], rename the original console as "Master Console".
# Place additional consoles such that they all attached to the same [[Wire Network]] connected to the "Master Console".
+
# Place additional consoles such that they all can be wired to the same wire-network connected to the Master-Console.
# Using the Labeller, rename each additional console as "Slave Console 1", "Slave Console 2" ...
+
# Using the [[Labeller]], rename each additional console as "Slave Console 1", "Slave Console 2" ...
# Insert [[Circuitboard (Advanced Airlock)]] into each additional console, then place a [[Glass Sheet]] onto the additional consoles.
+
# Insert Circuitboard (Advanced Airlock) into each additional console, then place the glass sheets onto the additional consoles.
# Insert [[Data Disk]] into the side slot of the powered on "Master Console".
+
# Insert Data Disk into the side slot of the powered on Master-Console.
# Use the "Master Console's" up and down arrows to scroll through the list of devices. Click to select. Click again to deselect if incorrect
+
# On the Master-Console, scroll through the list of devices. Click to select. Click again to deselect if incorrect
 
# Find and click "Slave Console #" followed by all caps and green "MAKE SLAVE" for each additional console.
 
# Find and click "Slave Console #" followed by all caps and green "MAKE SLAVE" for each additional console.
# Remove Data Disk from the side slot of "Master Console".
+
# Remove Data Disk from the side slot of Master-Console.
 
# Power on each additional console.
 
# Power on each additional console.
<br>If there is an error the console screen will say so and the power light will flash yellow.
+
 
 
 
==Troubleshooting==
 
==Troubleshooting==
When powered, all associated doors and vents are locked, preventing their manual use even when power is subsequently denied. This can be a problem when trapped within an airlock during a power outage. Best practise is to ensure the airlock's wire network is connected to an emergency [[Power Supply]] such as a [[Battery Cell]] equipped [[Power Controller]].
+
When powered, all associated doors and vents are locked, preventing their manual use even when power is denied. This can be a problem if trapped within an airlock during a power outage. Best practise is to ensure the airlocks wire-network is connected to an emergency power supply such as a [[Battery Cell]] equipped [[Power Controller]].
 
 
If the "External #Pa" or "Internal #Pa" are set to 0, the corresponding pressurization phase will be skipped, speeding up the cycle time, but can result in large wind currents when doors open.
 
  
A pressurization phase will stall if there is not enough gas available to the interior or exterior [[Active Vent]] to reach the set "Internal #Pa" or "External #Pa" specified in the [[Circuitboard (Advanced Airlock)#Settings|Circuitboard's settings]]. Such stalled pressurization can be skipped by clicking the yellow "Cancel Pressurize" button on a console.
+
An airlock may stall if there is not enough gas available from/through the pipe-network attached to the interior or exterior vent to reach the desired pressure set within the Circuitboard (Advanced Airlock). Such stalled pressurization phases can be skipped by clicking the yellow "Cancel Pressurize/Depressurize" button on a console. Note that a console can often be accessed through windows if needed. As a last resort, an airlock portal can be deconstructed.
  
A depressurization phase will stall if a complete vacuum cannot be achieved within the [[Large Grid Atmosphere|Large Grid Volume]]s in which all selected [[Gas Sensor]]s reside. Such stalled depressurization can be skipped by clicking the yellow "Cancel Depressurize" button on a console, but atmospheric mixing may occur. In larger airlocks, ensure there is one Gas Sensor per Large Grid to prevent premature repressurization and the resulting mixture of interior and exterior atmospheres.
+
An airlock depressurization phase will not complete until the large grid volume in which the Gas Sensor resides is depleted of atmosphere at which time the appropriate door will open. Thus in larger airlocks, ensure there is one Gas Sensor per large grid to prevent airlock doors from prematurely opening and the resulting mixture of interior and exterior atmospheres.
  
The setup of slave consoles <em>may</em> still be bugged in such a way that after initial setup the slave console will show the config of an airlock, but be grayed out and not accept any input. It has been noted in several community posts that saving the game, quitting out of the game, and then reloading the save will allow the slave consoles to work after the reload.
+
If the "External ###Pa" or "Internal ###Pa" are set to 0, the corresponding pressurization phase will be skipped, speeding up the cycle time, but can result in large wind currents when doors open.
  
 
==See Also==
 
==See Also==

Please note that all contributions to Unofficial Stationeers Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see Unofficial Stationeers Wiki:Copyrights for details). Do not submit copyrighted work without permission!

To edit this page, please answer the question that appears below (more info):

Cancel | Editing help (opens in new window)