Actions

Difference between revisions of "Control Chair"

From Unofficial Stationeers Wiki

(Update to use the new Structurebox syntax)
(Update to use the new Data Network templates)
Line 10: Line 10:
 
The '''Control Chair''' is a piece of furniture, which is constructed with the [[Kit (Furniture)]].
 
The '''Control Chair''' is a piece of furniture, which is constructed with the [[Kit (Furniture)]].
  
== Data Network Properties ==
+
{{Data Network Header}}
These are all [[:Category:Data Network|Data Network]] properties of this device.
 
  
=== Data Parameters ===
+
{{Data Parameters}}
These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
 
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 26: Line 24:
 
|}
 
|}
  
=== Data Outputs ===
+
{{Data Outputs}}
These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
 
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-

Revision as of 06:31, 8 July 2018

Control Chair
Operation
Power Usage 250W
Construction
Placed with Kit (Furniture)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Furniture)

The Control Chair is a piece of furniture, which is constructed with the Kit (Furniture).

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
Mode Integer (Unknown) Accepts a range from 0 to 2. Affects the Mode output.
Setting Float (Unknown) Accepts a range from 0.0 to 100.0. Affects the Setting output.
On Boolean (Unknown) Supposedly turns the Control Chair on, when set to 1. Turns it off, when set to 0. Affects the On output.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Control Chair is turned on and receives power. (0 for no, 1 for yes)
Mode Integer (Unknown) Returns a range from 0 to 2. Is affected by the Mode parameter.
Error Boolean Returns whether the Control Chair is flashing an error.
Setting Float (Unknown) Returns a range from 0.0 to 100.0. Is affected by the Setting parameter.
Maximum Integer (Unknown) Returns 100.
Ratio Float Returns a range from 0.0 to 1.0. Returns the ratio of the set Setting to the Maximum.
On Boolean Returns whether the Control Chair is turned on. (0 for no, 1 for yes)
RequiredPower Returns the power, currently needed by the Control Chair, in watts.