Actions

Kit (Satellite Dish)/Data Network

From Unofficial Stationeers Wiki

Revision as of 11:36, 11 September 2025 by 109.118.114.223 (talk) (Output Data (Read))
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

These are all of the Satellite_Dish parameter in the game.

Input Data (Write)[edit]

These are all parameters, that can be written to with different means of using logic.

Parameter Name Data Type Value Description
On Boolean 0 Turns the device off. Also toggles the switch accordingly.
1 Turns the device on. Also toggles the switch accordingly.
Activate Boolean 0 If the vessel's being interrogated, stop interrogating the vessel; or nothing.
1 If the vessel's has not been interrogated, start interrogating the vessel. If the vessel has been interrogated, call down the vessel to the TargetPadIndex.
Setting Integer 0 ~ Max watts of device. Set output watts to the specified number.
Horizontal Integer 0 ~ 360 Set dish's horizontal angle to the specified number.
Vertical Integer 0 ~ 90 Set dish's vertical angle to the specified number.
TargetPadIndex Integer Sets the landing pad index for potential call down.
BestContactFilter Integer Lock dish to track the specified ContactIDHash ONLY, set to -1 to unlock.
Update 0.2.5888.25957 - Sun 7/9/2025 /Data_Network

Output Data (Read)[edit]

These are all parameters, that can be read by using different means of logic.

Parameter Name Data Type Value Description
On Boolean 0 The Dish is not powered. This is the same as the physical red powerswitch located on the structure.
1 The Dish is powered. This is the same as the physical red powerswitch located on the structure.
Activate Boolean 0 Read out current Activate value; if Activate == 1, it means the dish is either interrogating the vessel or the vessel is just coming down to landing pad.
Setting Integer Read out current dish's output watts.
Horizontal Integer Read out current dish's horizontal angle.
Vertical Integer Read out current dish's vertical angle.
RequiredPower Integer Idle operating power quantity. Does not include extra power during actual usage.
Idle Boolean Read out if the dish is not moving.
Idle Boolean 0 Dish not moving, and not interrogating.
1 Dish is either moving or interrogating.
Error Boolean 0 1 if device is in error state, otherwise 0.
1 1 if device is in error state, otherwise 0.
SignalStrength Integer The signal strength of currently tracking signal, negative value, larger is better.
If the dish is moving, this value always show -1.
SignalID Integer The signal IDHASH of currently tracking signal.
InterrogationProcess Integer This value only has meaning if the dish has started interrogation to the vessel.
Show's percentage on the process of the interrogation.
TargetPadIndex Integer Read out current value of target landing pad index, useful if you want to call down the vessel by code.
SizeX Integer The length on X axis of the vessel, see SHUTTLE_TYPE.
SizeZ Integer The length on Z axis of the vessel, see SHUTTLE_TYPE.
Reagents Integer Total number of reagents inside the device (e.g. 92g of iron = 92).
MinimumWattsToContact Integer The minimum watts required reaching target vessel before one can initiate interrogation.
This is the requirement imposed by the vessel.
WattsReachingContact Integer The current effective watts reached target vessel due to angle setting and dish's watts output setting.
ContactTypeId Integer The category of the vessel, see ContactTypeID.
BestContactFilter Integer Currently locked ContactID, or -1 if not set.
StackSize Integer Read out the stack Byte count of the structure.
NameHash Integer The hash of the custom name of the structure.
PrefabHash Integer The hash of the structure.
Referenceld Integer Unique Reference Identifier for this object.
Update 0.2.5888.25957 - Sun 7/9/2025 /Data_Network