Difference between revisions of "Kit (Atmospherics) Filtration"
From Unofficial Stationeers Wiki
Ipottinger (talk | contribs) (Redirected page to Atmospherics#Filtration) |
Ipottinger (talk | contribs) m (Initial Content) |
||
Line 1: | Line 1: | ||
− | + | [[Category:Atmospherics]] | |
+ | <languages/> | ||
+ | <translate> | ||
+ | {{Structurebox | ||
+ | | name = Filtration | ||
+ | | power_usage = 5w | ||
+ | | placed_with_item = [[Kit (Atmospherics)]] | ||
+ | | placed_on_grid = Small Grid | ||
+ | | decon_with_tool1 = [[Hand Drill]] | ||
+ | | item_rec1 = [[Kit (Atmospherics)]] | ||
+ | }} | ||
+ | ==Purpose== | ||
+ | A Filtration unit is a powered Atmospheric processor used to filter specific gases from a mixture. [[Guide (Filtration)]] provides additional information regarding the function, construction, and operation of a Filtration unit. | ||
+ | |||
+ | <!--T:2--> | ||
+ | ==Characteristics== | ||
+ | * It has a manual power switch. | ||
+ | * It consumes 5W of [[Power]] per [[Tick]] when idle or active. | ||
+ | * It has a separate [[Power Port]] and [[Data Port]]. | ||
+ | * It has a pipe port (labelled "Input") for the gas mixture from which the designated gas(es) '''will be''' filtered. | ||
+ | * It has a pipe port (labelled "Filtered") for the designated gas(es) that '''have been''' filtered. | ||
+ | * It has a pipe port (labelled "Unfiltered") for any remaining unfiltered gases. | ||
+ | * It can filter up to 2 different gases at once by inserting two different filters. | ||
+ | |||
+ | <!--T:3--> | ||
+ | ==User Interface== | ||
+ | A Filtration unit provides the following user interface: | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! Name || Type !! Function | ||
+ | |- | ||
+ | | [[Filters|Filter]] (Right) || Slot || Port for a gas filter. If gas of the same type is present in the incoming mixture, it will be redirected out the "Filtered" pipe port. | ||
+ | |- | ||
+ | | Filter (Left) || Slot || Another Port for a gas filter that functions the same as its twin slot. May contain the same or a different filter. | ||
+ | |- | ||
+ | | On/Off|| Switch || Switches Filtration unit between turned on or turned off. | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | {{Data Network Header}} | ||
+ | |||
+ | {{Data Parameters}} | ||
+ | <!--T:4--> | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! Parameter Name !! Data Type !! Description | ||
+ | |- | ||
+ | | On || Boolean || Powers on the Filtration unit on when set to 1. Powers off when set to 0. | ||
+ | |} | ||
+ | |||
+ | {{Data Outputs}} | ||
+ | <!--T:5--> | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! Output Name !! Data Type !! Description | ||
+ | |- | ||
+ | | Power || Boolean || Returns whether the Filtration unit is turned on and receives power. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | Error || Boolean || Returns whether the Filtration unit is flashing an error. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | Lock || Boolean || Returns whether the Filtration unit is locked. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | On || Boolean || Returns whether the Filtration unit is turned on. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | RequiredPower || Integer || Returns the current amount of power in Watts required by the Filtration unit. | ||
+ | |- | ||
+ | | Quantity || Integer || Returns the current amount of Filter remaining. Slot 0 (Right), slot 1 (Left). | ||
+ | |} | ||
+ | |||
+ | <!--T:6--> | ||
+ | ==See Also== | ||
+ | * [[Guide (Filtration)]] | ||
+ | |||
+ | * [[Kit (Atmospherics)]] | ||
+ | * [[Kit (Portable Scrubber) Portable Scrubber|Portable Scrubber]] | ||
+ | </translate> |
Revision as of 02:53, 17 October 2019
Operation | |
---|---|
Power Usage | 5w |
Construction | |
Placed with | Kit (Atmospherics) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Atmospherics) |
Contents
Purpose
A Filtration unit is a powered Atmospheric processor used to filter specific gases from a mixture. Guide (Filtration) provides additional information regarding the function, construction, and operation of a Filtration unit.
Characteristics
- It has a manual power switch.
- It consumes 5W of Power per Tick when idle or active.
- It has a separate Power Port and Data Port.
- It has a pipe port (labelled "Input") for the gas mixture from which the designated gas(es) will be filtered.
- It has a pipe port (labelled "Filtered") for the designated gas(es) that have been filtered.
- It has a pipe port (labelled "Unfiltered") for any remaining unfiltered gases.
- It can filter up to 2 different gases at once by inserting two different filters.
User Interface
A Filtration unit provides the following user interface:
Name | Type | Function |
---|---|---|
Filter (Right) | Slot | Port for a gas filter. If gas of the same type is present in the incoming mixture, it will be redirected out the "Filtered" pipe port. |
Filter (Left) | Slot | Another Port for a gas filter that functions the same as its twin slot. May contain the same or a different filter. |
On/Off | Switch | Switches Filtration unit between turned on or turned off. |
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
On | Boolean | Powers on the Filtration unit on when set to 1. Powers off when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Filtration unit is turned on and receives power. (0 for no, 1 for yes) |
Error | Boolean | Returns whether the Filtration unit is flashing an error. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Filtration unit is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Filtration unit is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power in Watts required by the Filtration unit. |
Quantity | Integer | Returns the current amount of Filter remaining. Slot 0 (Right), slot 1 (Left). |