Actions

Template

Difference between revisions of "Data Parameters"

From Unofficial Stationeers Wiki

(add a way to skip intro text)
m (Data Parameters)
 
(2 intermediate revisions by 2 users not shown)
Line 2: Line 2:
 
{{#if: {{{1|}}}
 
{{#if: {{{1|}}}
 
|{{#if:{{{skip_intro|}}}||These are all parameters that can be written with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]], [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]], or [[Integrated Circuit (IC10)]], and can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]], [[Kit_(Logic_I/O)#Batch_Reader|Batch Reader]], or [[Integrated Circuit (IC10)]].}}
 
|{{#if:{{{skip_intro|}}}||These are all parameters that can be written with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]], [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]], or [[Integrated Circuit (IC10)]], and can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]], [[Kit_(Logic_I/O)#Batch_Reader|Batch Reader]], or [[Integrated Circuit (IC10)]].}}
 +
<div class="mw-customtoggle-datanetworkproperties-{{PAGENAMEE}}" style="width:auto; overflow:auto; text-indent:10px; border: 2px solid #253C60; border-radius:10px;"><b>Click here to see/hide all the <span style="color:#E57125;">data network properties</span></b></div>
 +
<div class="mw-collapsible mw-collapsed" id="mw-customcollapsible-datanetworkproperties-{{PAGENAMEE}}">
 
{{{!}} class="wikitable sortable large"
 
{{{!}} class="wikitable sortable large"
 
! Parameter Name
 
! Parameter Name
Line 13: Line 15:
 
}}
 
}}
 
{{!}}}
 
{{!}}}
 +
</div>
 
|{{#if: {{{empty|}}}|This device does not have any logic parameters and can not be selected with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]].| These are all parameters that can be written with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]], [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]], or [[Integrated Circuit (IC10)]]. }}
 
|{{#if: {{{empty|}}}|This device does not have any logic parameters and can not be selected with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]].| These are all parameters that can be written with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]], [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]], or [[Integrated Circuit (IC10)]]. }}
 
}}
 
}}
Line 23: Line 26:
 
{{Data Parameters/row|Mode|Integer|The mode of the Sorter, '''Split''' does alternate outputs, '''Filter''' decides output via [[Motherboard (Sorter)]], '''Logic''' determines output via parameter '''Output'''|multiple=3|0|Split|1|Filter|2|Logic}}
 
{{Data Parameters/row|Mode|Integer|The mode of the Sorter, '''Split''' does alternate outputs, '''Filter''' decides output via [[Motherboard (Sorter)]], '''Logic''' determines output via parameter '''Output'''|multiple=3|0|Split|1|Filter|2|Logic}}
 
{{Data Parameters/row|Error|Boolean|w=0|1 if device is in error state, otherwise 0|multiple=2|0|<p></p>|1|Error}}
 
{{Data Parameters/row|Error|Boolean|w=0|1 if device is in error state, otherwise 0|multiple=2|0|<p></p>|1|Error}}
{{Data Parameters/row|Lock|Boolean|Disable manual operation of the Sorter.|multiple=2|0|Unlocked|1|Locked}}
+
{{Data Parameters/row|Activate|Boolean|w=1|1 if device is activated (usually means running), otherwise 0|multiple=2|0|<p></p>|1|Activated}}
{{Data Parameters/row|On|Integer|The current state of the Sorter.|multiple=2|0|On|1|Off}}
+
{{Data Parameters/row|Lock|Boolean|w=1|Disable manual operation of the Ice Crusher.|multiple=2|0|Unlocked|1|Locked}}
 +
{{Data Parameters/row|Setting|Boolean|w=1|The target temperature of the crushed ice in Kelvin}}
 +
{{Data Parameters/row|Maximum|Boolean|w=0|The maximum temperature in Kelvin applicable to Setting}}
 +
{{Data Parameters/row|Ratio|Float|w=0|A value between 0 and 1.}}
 +
{{Data Parameters/row|On|Integer|w=0|The current state of the Sorter.|multiple=2|0|On|1|Off}}
 
{{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}}
 
{{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}}
 
{{Data Parameters/row|ClearMemory|Integer|r=0|When set to 1, clears the counter memory (e.g. ExportCount). Will set itself back to 0 when actioned}}  
 
{{Data Parameters/row|ClearMemory|Integer|r=0|When set to 1, clears the counter memory (e.g. ExportCount). Will set itself back to 0 when actioned}}  
{{Data Parameters/row|ExportCount|Integer|w=0|How many items exported since last ClearMemory}}
 
 
{{Data Parameters/row|ImportCount|Integer|w=0|How many items imported since last ClearMemory}}
 
{{Data Parameters/row|ImportCount|Integer|w=0|How many items imported since last ClearMemory}}
{{Data Parameters/row|Output|Integer|In Logic mode, decides which side the next item will be sent to. (defaults to -1 after action)|multiple=3|-1|Unset|0|Straight|1|Side}}
 
 
{{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}}
 
{{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}}
 
{{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}}
 
{{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}}

Latest revision as of 13:04, 25 November 2025

Data Parameters[edit]

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Template documentation[view] [edit] [history] [purge]

Data Parameters template[edit]

This template is meant to be used for Structures, that support connections to the Data Network. It provides a heading for Data parameters. If anything is passed to the first positional parameter of the template, it will display a text that indicates, that the structure does not have any parameters.

Data Parameters[edit]

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).

Click here to see/hide all the data network properties
Parameter Name Data Type Access Value Description
Power Boolean
Read
0 Off Can be read to return if the device is correctly powered or not, set via the power system, return 1 if powered and 0 if not
1 On
Mode Integer
Read Write
0 Split The mode of the Sorter, Split does alternate outputs, Filter decides output via Motherboard (Sorter), Logic determines output via parameter Output
1 Filter
2 Logic
Error Boolean
Read
0

1 if device is in error state, otherwise 0
1 Error
Activate Boolean
Read Write
0

1 if device is activated (usually means running), otherwise 0
1 Activated
Lock Boolean
Read Write
0 Unlocked Disable manual operation of the Ice Crusher.
1 Locked
Setting Boolean
Read Write
The target temperature of the crushed ice in Kelvin
Maximum Boolean
Read
The maximum temperature in Kelvin applicable to Setting
Ratio Float
Read
A value between 0 and 1.
On Integer
Read
0 On The current state of the Sorter.
1 Off
RequiredPower Integer
Read
Idle operating power quantity, does not necessarily include extra demand power
ClearMemory Integer
Write
When set to 1, clears the counter memory (e.g. ExportCount). Will set itself back to 0 when actioned
ImportCount Integer
Read
How many items imported since last ClearMemory
PrefabHash Integer
Read
The hash of the structure
ReferenceId Integer
Read
Unique Reference Identifier for this object
NameHash Integer
Read
Provides the hash value for the name of the object as a 32 bit integer.