Difference between revisions of "Sorter"
From Unofficial Stationeers Wiki
Emilgardis (talk | contribs) (update params and remove logic sorter and kit) |
Emilgardis (talk | contribs) (fix heading) |
||
Line 44: | Line 44: | ||
}} | }} | ||
− | + | === Data Slots === | |
These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Slots_Reader|Slots Reader]]. The outputs are listed in the order a Slots Reader's "VAR" setting cycles through them. | These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Slots_Reader|Slots Reader]]. The outputs are listed in the order a Slots Reader's "VAR" setting cycles through them. | ||
{| class="wikitable" | {| class="wikitable" |
Revision as of 02:44, 20 May 2024
Operation | |
---|---|
Power Usage | 5W |
Prefab Hash | -1009150565 |
Prefab Name | StructureSorter |
Construction | |
Placed with | Kit (Sorter) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Sorter) |
Contents
Description
No amount of automation is complete without some way of moving different items to different parts of a system. The Xigo A2B sorter can be programmed via a computer with a Sorter Motherboard to direct various items into different chute networks. Filtered items are always passed out the righthand side of the sorter, while non filtered items continue straight through.
- Stationpedia
When the Mode is set to 0 or if there is no WhiteList configured on a computer, the Sorter will act as a splitter: items will alternate their output lane each time. The Output property will switch value accordingly.
When controlled by a computer with a Motherboard (Sorter) you can whitelist item(s) or itemgroup(s) and discard the rest out the alternate lane. If you are looking at the output side of the machine (with the power switch on your right) whitelist output is left, discarded items output is right.
Changing Output or Mode via logic or IC can cause an item to get stuck in the sorter until the logic circuit or IC command the Output to either 0 or 1. This behavior is normal. After the first output, the Output variable is set to -1. This is normal behavior and a reset circuit (using logic chips) or Output loop (using IC) will serve the purpose of using the ports properly so long as they send the Output variable after each item enters the sorter.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Sorter is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Mode | Integer | Read Write
|
0 | Split | The mode of the Sorter, Split does alternate outputs, Filter decides output via Motherboard (Sorter), Logic determines output via parameter Output | |
1 | Filter | |||||
2 | Logic | |||||
Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
1 | Error | |||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Sorter. | |
1 | Locked | |||||
On | Boolean | Read Write
|
0 | Off | The current state of the Sorter. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
ClearMemory | Integer | Write
|
||||
ExportCount | Integer | Read
|
||||
ImportCount | Integer | Read
|
||||
Output | Integer | Read Write
|
-1 | Unset | Decides which side the next item will be sent to.
In Logic mode, defaults to -1 after action. In Split mode, alternates between 0 and 1 after action. Does nothing in Filter mode. | |
0 | Straight | |||||
1 | Side | |||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|
Data Slots
These are all parameters, that can be read with a Slots Reader. The outputs are listed in the order a Slots Reader's "VAR" setting cycles through them.
Number | Name | Description |
---|---|---|
0 | Import | Import slot. |
1 | Export (accept) | Export slot. |
2 | Export (reject) | Export slot. |
3 | Data Disk | Diskslot |
Name | Data Type | Description |
---|---|---|
MaxQuantity | Integer | Returns maximum stacksize. |
Damage | Integer | Item durability in percent. |
Class | Integer | Item class ID. |
Quantity | Integer | Size of stack. |
PrefabHash | Integer | Returns ItemHash of item in slot. |
Occupied | Boolean | Returns whether the slot occupied. (0 for no, 1 for yes). |
OccupantHash | Integer | Returns ItemHash of item in slot. |
Item Slot Classes / Types
Reading the class attribute of the input slot will give one of the following values:
Note that you can useSlotClass.<Item>directly in IC code instead of the numeric value
- NOTE The classes listed in this section are FilterSlotTypeCompare and NOT sorting class.
Item | Value | Description | Item | Value | Description | Item | Value | Description |
---|---|---|---|---|---|---|---|---|
None | 0 | Helmet | 1 | Suit | 2 | |||
Back | 3 | GasFilter | 4 | GasCanister | 5 | |||
Motherboard | 6 | Circuitboard | 7 | DataDisk | 8 | |||
Organ | 9 | Ore | 10 | Includes reagent mixes from recycler and ices | Plant | 11 | ||
Uniform | 12 | Entity | 13 | Battery | 14 | |||
Egg | 15 | Belt | 16 | Tool | 17 | |||
Appliance | 18 | Ingot | 19 | Torpedo | 20 | |||
Cartridge | 21 | AccessCard | 22 | Magazine | 23 | |||
Circuit | 24 | Bottle | 25 | ProgrammableChip | 26 | |||
Glasses | 27 | CreditCard | 28 | DirtCanister | 29 | |||
SensorProcessingUnit | 30 | LiquidCanister | 31 | LiquidBottle | 32 | |||
Wreckage | 33 | SoundCartridge | 34 | DrillHead | 35 | |||
ScanningHead | 36 | Flare | 37 | Blocked | 38 | |||
SuitMod | 39 |