|
|
(2 intermediate revisions by 2 users not shown) |
Line 1: |
Line 1: |
− | [[Category:Atmospherics]] | + | #REDIRECT [[Filtration]] |
− | <languages/>
| |
− | <translate>
| |
− | {{Structurebox
| |
− | | name = Filtration
| |
− | | power_usage = 5w
| |
− | | placed_with_item = [[Kit (Atmospherics)]]
| |
− | | placed_on_grid = Small Grid
| |
− | | decon_with_tool1 = [[Hand Drill]]
| |
− | | item_rec1 = [[Kit (Atmospherics)]]
| |
− | }}
| |
− | <!--T:1-->
| |
− | ==Purpose==
| |
− | A Filtration unit is a powered Atmospheric processor used to filter specific gases from a mixture. [[Guide (Filtration)]] provides additional information regarding the function, construction, and operation of a Filtration unit.
| |
− | | |
− | <!--T:2-->
| |
− | ==Characteristics==
| |
− | * It has a manual power switch.
| |
− | * It consumes 10W of [[Power]] per [[Tick]] when idle and 44W when active.
| |
− | * It has a separate [[Power Port]] and [[Data Port]].
| |
− | * It has a pipe port (labelled "Input") for the gas mixture from which the designated gas(es) '''will be''' filtered.
| |
− | * It has a pipe port (labelled "Filtered") for the designated gas(es) that '''have been''' filtered.
| |
− | * It has a pipe port (labelled "Unfiltered") for any remaining unfiltered gases.
| |
− | * It can filter up to 2 different gases at once by inserting two different filters.
| |
− | Note: When using an I/O slot reader chip, the filter slots are labeled as slot 1 and slot 2, with 1 being the slot closer to the inlet.
| |
− | When using an IC chip, the slots are labeled as slot 0 and slot 1.
| |
− | | |
− | ==User Interface==
| |
− | A Filtration unit provides the following user interface:
| |
− | {| class="wikitable"
| |
− | |-
| |
− | ! Name || Type !! Function
| |
− | |-
| |
− | | [[Filters|Filter]] (Right) || Slot || Port for a gas filter. If gas of the same type is present in the incoming mixture, it will be redirected out the "Filtered" pipe port.
| |
− | |-
| |
− | | Filter (Left) || Slot || Another Port for a gas filter that functions the same as its twin slot. May contain the same or a different filter.
| |
− | |-
| |
− | | Programmable Chip || Slot || IC10 placed in filtration unit (has 2 Input/Outputs)
| |
− | |-
| |
− | | On || Switch || Switches Filtration unit between turned on or turned off. (On=1/Off=0)
| |
− | |-
| |
− | |}
| |
− | | |
− | {{Data Network Header}}
| |
− | | |
− | {{Data Parameters}}
| |
− | <!--T:4-->
| |
− | {| class="wikitable"
| |
− | |-
| |
− | ! Parameter Name !! Data Type !! Description
| |
− | |-
| |
− | | On || Boolean || Powers on the Filtration unit on when set to 1. Powers off when set to 0.
| |
− | |-
| |
− | | Open || Boolean ||
| |
− | |-
| |
− | | Setting || Integer ||
| |
− | |-
| |
− | | Lock || Boolean ||
| |
− | |-
| |
− | | Mode || Boolean ||
| |
− | |}
| |
− | | |
− | {{Data Outputs}}
| |
− | <!--T:5-->
| |
− | {| class="wikitable"
| |
− | |-
| |
− | ! Output Name !! Data Type !! Description
| |
− | |-
| |
− | | Power || Boolean || Returns whether the Filtration unit is turned on and receives power. (0 for no, 1 for yes)
| |
− | |-
| |
− | | Error || Boolean || Returns whether the Filtration unit is flashing an error. (0 for no, 1 for yes)
| |
− | |-
| |
− | | Lock || Boolean || Returns whether the Filtration unit is locked. (0 for no, 1 for yes)
| |
− | |-
| |
− | | On || Boolean || Returns whether the Filtration unit is turned on. (0 for no, 1 for yes)
| |
− | |-
| |
− | | RequiredPower || Integer || Returns the current amount of power in Watts required by the Filtration unit.
| |
− | |-
| |
− | | Quantity || Integer || Returns the current amount of Filter remaining. Slot 0 (Right), slot 1 (Left).
| |
− | |}
| |
− | | |
− | Slot Outputs
| |
− | | |
− | {| class="wikitable"
| |
− | |-
| |
− | ! Output Name !! Data Type !! Description
| |
− | |-
| |
− | | OccupantHash || Integer || Filter cartridge Hash-code (Identifier)
| |
− | |-
| |
− | | Occupied || Boolean || 0/1 filter slot empty/occupied
| |
− | |-
| |
− | | PrefabHash || Integer ||
| |
− | |-
| |
− | | Quantity || Integer || Remaining life of filter cartridge.
| |
− | |-
| |
− | | Class || Integer ||
| |
− | |-
| |
− | | Dammage || Integer ||
| |
− | |-
| |
− | | MaxQuantity || Integer || Max. life of filter cartridge
| |
− | |}
| |
− | | |
− | <!--T:6-->
| |
− | ==See Also==
| |
− | * [[Guide (Filtration)]]
| |
− | | |
− | * [[Kit (Atmospherics)]]
| |
− | * [[Kit (Portable Scrubber) Portable Scrubber|Portable Scrubber]]
| |
− | </translate>
| |