Actions

Editing Passive Vent

Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.

The edit can be undone. Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision Your text
Line 7: Line 7:
 
  | createdwith = [[Hydraulic Pipe Bender]], [[Fabricator]]
 
  | createdwith = [[Hydraulic Pipe Bender]], [[Fabricator]]
 
  | cost        = 3g [[Iron]]
 
  | cost        = 3g [[Iron]]
| volume      = 100L
 
 
}}
 
}}
  
 
== Description == <!--T:1-->
 
== Description == <!--T:1-->
<blockquote><q>This kit creates a Passive Vent among other variants.</q><br>
 
'''- Stationpedia'''</blockquote>
 
 
 
Permits gasses to go through when connected to a pipe network.  
 
Permits gasses to go through when connected to a pipe network.  
  
You can think of a passive vent as removing the end cap of a pipe system. A pipe on its own - even if it visually looks different! - is always closed on both ends (unless devices are attached to the end of the pipe). So there will be no exchange of gases between the pipe and the surrounding environment. Heat may be exchanged, but no gasses!
+
You can think of a passive vent as removing the end cap of a pipe system. A pipe on it's own - even if it visually looks different! - is always closed on both ends (unless devices are attached to the end of the pipe). So there will be no exchange of gases between the pipe and the surrounding environment. Heat may be exchanged, but no gases!
  
 
If you place a passive vent on the end of a pipe, the pipe and the surrounding environment will basically become one and the same "system". That means the gas mixture in the pipe and the surrounding environment will instantly(!) average out (which may affect the pressure, temperature and mixture of both the pipe and the surrounding environment) and will always be identical after that initial "evening out".
 
If you place a passive vent on the end of a pipe, the pipe and the surrounding environment will basically become one and the same "system". That means the gas mixture in the pipe and the surrounding environment will instantly(!) average out (which may affect the pressure, temperature and mixture of both the pipe and the surrounding environment) and will always be identical after that initial "evening out".
  
There is no other active component needed for this "evening out" between the pipe and the surrounding environment to happen; the passive vent does this on its own.
+
There is no other active component needed for this "evening out" between the pipe and the surrounding environment to happen, the passive vent does this on it's own.
  
But there will be no gas exchange beyond this "evening out". So if you, e.g. want to transport gas from a room through a passive vent and its attached pipe system to somewhere else, you need an active component - like an active vent, a pump or filtration unit, etc. - somewhere along the pipe.
+
But there will be no gas exchange beyond this "evening out". So if you, e.g. want to transport gas from a room through a passive vent and it's attached pipe system to somewhere else, you need an active component - like an active vent, a pump or filtration unit etc. - somewhere along the pipe.
 
</translate>
 
</translate>
  
== See also ==
+
[[Category:Atmospherics]]
[[Pipe Cowl]]
 
 
 
[[Category:Atmospherics]][[Category:Item]]
 

Please note that all contributions to Unofficial Stationeers Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see Unofficial Stationeers Wiki:Copyrights for details). Do not submit copyrighted work without permission!

To edit this page, please answer the question that appears below (more info):

Cancel | Editing help (opens in new window)

Templates used on this page: