Actions

Difference between revisions of "Wall Cooler"

From Unofficial Stationeers Wiki

m (deleted obsolete entry related to water as coolant gas, changes requirement in the description from "Pipe Radiator" to "Coolant gas pipe", some minor changes in the usage part to avoid misunderstandings)
 
(4 intermediate revisions by 3 users not shown)
Line 12: Line 12:
 
  | name            = Wall Cooler
 
  | name            = Wall Cooler
 
  | image            = [[File:{{#setmainimage:WallCooler.png}}]]
 
  | image            = [[File:{{#setmainimage:WallCooler.png}}]]
  | power_usage      = 5W
+
  | power_usage      = 10W idle + 1000W active
 
  | placed_with_item = [[Wall Cooler (Item)]]
 
  | placed_with_item = [[Wall Cooler (Item)]]
 
  | placed_on_grid  = Small Grid, On Frames
 
  | placed_on_grid  = Small Grid, On Frames
Line 22: Line 22:
 
Used to lower the temperature inside a room.
 
Used to lower the temperature inside a room.
 
It will flash an error if certain things are not present like:
 
It will flash an error if certain things are not present like:
* [[Pipe Radiator]]
+
* Coolant gas pipe
* Atmosphere in the room you're trying to cool
+
* Atmosphere in the room you're trying to cool (minimum is around 5-8kpa, not sure exactly, will flash an error if too low)
* gasses in the coolant pipe (At least 12.5 kpa)
+
* Gasses in the coolant pipe (At least 12.5 kpa)
  
 
Game update 0.2.1783.8193 Changed the wall cooler where the efficiency drops as the temperature difference becomes too large. If the waste network becomes 100 degrees warmer than input, efficiency begins to drop until zero at 200 degrees. This is highlighted on the graph on the right. [[File:Cooler Graph.png|thumb|Efficiency drop off]]
 
Game update 0.2.1783.8193 Changed the wall cooler where the efficiency drops as the temperature difference becomes too large. If the waste network becomes 100 degrees warmer than input, efficiency begins to drop until zero at 200 degrees. This is highlighted on the graph on the right. [[File:Cooler Graph.png|thumb|Efficiency drop off]]
  
 
==Usage== <!--T:2-->
 
==Usage== <!--T:2-->
Place the Wall Cooler and run some pipes to the place you want to vent the heat. Place a few Pipe radiators on the pipe, fill it with whatever gasmixture you want and start the machine, it will slowly lower the temperature.
+
Place the Wall Cooler and run some pipes to the place you want to store or vent the heat. Fill the coolant pipe with enough gas and start the machine, it will slowly lower the rooms temperature by transfering its heat to the coolant pipe.
  
 
<!--T:3-->
 
<!--T:3-->
* Best coolant for now Water, but Pollutant aka X is more abundant.
 
 
* The wall cooler works by removing 1000 Joules of energy/tick (2000J/s) from the atmosphere and adding it into its pipe.
 
* The wall cooler works by removing 1000 Joules of energy/tick (2000J/s) from the atmosphere and adding it into its pipe.
  

Latest revision as of 16:58, 28 July 2021

Other languages:
English
Wall Cooler
Stacks 5
Recipe
Created With Hydraulic Pipe Bender, Fabricator
Cost 3g Iron, 1g Gold, 3g Copper
Wall Cooler
WallCooler.png
Operation
Power Usage 10W idle + 1000W active
Construction
Placed with Wall Cooler (Item)
Placed on Small Grid, On Frames
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Wall Cooler (Item)

Description[edit]

Used to lower the temperature inside a room. It will flash an error if certain things are not present like:

  • Coolant gas pipe
  • Atmosphere in the room you're trying to cool (minimum is around 5-8kpa, not sure exactly, will flash an error if too low)
  • Gasses in the coolant pipe (At least 12.5 kpa)
Game update 0.2.1783.8193 Changed the wall cooler where the efficiency drops as the temperature difference becomes too large. If the waste network becomes 100 degrees warmer than input, efficiency begins to drop until zero at 200 degrees. This is highlighted on the graph on the right.
Efficiency drop off

Usage[edit]

Place the Wall Cooler and run some pipes to the place you want to store or vent the heat. Fill the coolant pipe with enough gas and start the machine, it will slowly lower the rooms temperature by transfering its heat to the coolant pipe.

  • The wall cooler works by removing 1000 Joules of energy/tick (2000J/s) from the atmosphere and adding it into its pipe.


Data Network Properties[edit]

These are all Data Network properties of this device.

Data Parameters[edit]

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
Lock
Setting Boolean Unused
On

Data Outputs[edit]

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power
Error
Lock
Setting
Maximum
Ratio
On
Required Power