Actions

Hydroponics Station

From Unofficial Stationeers Wiki

Revision as of 14:25, 13 October 2018 by Daedrias (talk | contribs) (lower yield for potatoes at least)
Kit (Hydroponic Station)
Recipe
Created With Electronics Printer
Cost

Placeholder icon.png

5


Placeholder icon.png

20


Placeholder icon.png

10


Placeholder icon.png

5
Hydroponics Station
Construction
Placed with Kit (Hydroponic Station)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Hydroponic Station)

Usage

This item is used to grow crops, similar to the Hydroponic Tray, with the following differences

  • It is slightly more expensive, but it comes with 4 grow slots, and takes up a 3x3 area.
  • It includes a grow light which can grow all 4 crops without sunlight, but requires 100W of power when turned on.
  • It can grow from seed plant to harvest: 2x wheat in about 6 minutes, 2x corn in about 11 minutes, 3x potato in about 8.5 minutes, 2x soybean in about 9 minutes, 2x fern in about 9 minutes
  • It has a data output port (more details needed)
  • It seems to have a lower yield than the tray : even if the tooltip indicate that 3 potatoes can be harvested, you get only two.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Return whether the UV light of the station is on. (1 for on, 0 for off)
Pressure * Float Pressure of the fluid alimenting the station.
Temperature * Float in kelvins. Temprature of the
Setting Integer
RatioOxygen* Float Ratio of oxygen in the fluid alimenting the station.
RatioCarbonDioxide * Float
RatioNitrogen * Float
RatioPollutant * Float
RatioVolatiles * Float
RatioWater * Float
Maximum Integer Value of 100.
Ratio Float Seems to be the ratio between the Setting and the Maxium. So 0.5
On Boolean Return whether the UV light of the station is on. (1 for on, 0 for off)
RequiredPower Integer In watts. 0 if the lamp is off, 100 if it's on.
 * The Pressure, Temperature and ratios parameters are mesured from the fluid alimenting the station, not from the surrounding atmosphere.