Actions

Difference between revisions of "Electrolyzer"

From Unofficial Stationeers Wiki

m (structure)
m (Undo revision 8998 by 96.8.168.253 (talk))
Line 14: Line 14:
 
Place the Kit (Atmospherics) and change the variant to Electrolyzer.<br>
 
Place the Kit (Atmospherics) and change the variant to Electrolyzer.<br>
 
There are two pipe connections.<br>
 
There are two pipe connections.<br>
Electrolyzer Output is where you connect the incoming water.<br>
+
Electrolyzer Input is where you connect the incoming water.<br>
Electrolyzer Input is where the H<sub>2</sub> and O<sub>2</sub> comes out mixed together.
+
Electrolyzer Output is where the H<sub>2</sub> and O<sub>2</sub> comes out mixed together.
  
 
{{Data Network Header}}
 
{{Data Network Header}}

Revision as of 10:56, 30 May 2020

Electrolyzer
Electrolyzer front.png
Operation
Power Usage 1200W
Construction
Placed with Kit (Atmospherics)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Atmospherics)

Storing water got you down? At the expense of power, you can turn that excess water into a bunch of heat and a somewhat risky mix of Oxygen and Volatiles using the new Electrolysis Machine. Available on the existing Atmospherics kit with Air Conditioners and Filtration machines.

Usage

Place the Kit (Atmospherics) and change the variant to Electrolyzer.
There are two pipe connections.
Electrolyzer Input is where you connect the incoming water.
Electrolyzer Output is where the H2 and O2 comes out mixed together.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
Lock Boolean Locks the Electrolyzer , when set to 1. Unlocks it, when set to 0.
On Boolean Turns the Electrolyzer on, when set to 1. Turns it off, when set to 0.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Electrolyzer is turned on and receives power. (0 for no, 1 for yes)
Error Boolean Returns whether the Electrolyzer is flashing an error. (0 for no, 1 for yes)
Lock Boolean Returns whether the Electrolyzer is locked. (0 for no, 1 for yes)
On Boolean Returns whether the Electrolyzer is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power, required by the Electrolyzer, in Watts.