Actions

Difference between revisions of "Dock Port Side"

From Unofficial Stationeers Wiki

(Update to use the new Structurebox syntax)
(Update to use the new Data Network templates)
Line 17: Line 17:
 
}}
 
}}
  
== Data Network Properties ==
+
{{Data Network Header}}
These are all [[:Category:Data Network|Data Network]] properties of this device.
 
  
=== Data Parameters ===
+
{{Data Parameters}}
These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
 
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 33: Line 31:
 
|}
 
|}
  
=== Data Outputs ===
+
{{Data Outputs}}
These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
 
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-

Revision as of 06:34, 8 July 2018

Kit (Docking Port)
Stacks 5
Dock Port Side
Operation
Power Usage -1W
Construction
Placed with Kit (Docking Port)
Placed on Large Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Docking Port)

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
Open Boolean Opens the Docking Port, when set to 1. Closes the it, when set to 0.
Lock Boolean Locks the Docking Port, when set to 1. Unlocks it, when set to 0.
On Boolean Turns the Docking Port on, when set to 1. Turns the Docking Port off, when set to 0.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Docking Port is turned on and receives power. (0 for no, 1 for yes) (Assumption)
Open Boolean Returns whether the Docking Port is open. (0 for no, 1 for yes)
Lock Boolean Returns whether the Docking Port is locked. (0 for no, 1 for yes)
On Boolean Returns whether the Docking Port is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power, required by the Docking Port, in Watts.

Bugs

  • The Docking Port can not be powered, as indicated by the RequiredPower of -1W.